NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
R Tel. 212-353-8280
Fax 212-353-8306
Hl
REPORT DATE: 07-25-02
n CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
n 345 Chambers Street, NY
PROJECT NUMBER: M477-15217/29881
H
SAMPLED BY: Client
SAMPLE DATE: 07-25-02
DATE RECEIVED: 07-25-02
DATE ANALYZED: 07-25-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSTS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(Pg/ft^ (ng/ft")
LW-01 20658 Rm 525 Right Unitvent Rear <9.0 9.0
LW-02 20658 Rm 525 Left Unitvent Rear <9.0 9.0
LW-03 20658 Rm 513 Left Unitvent Rear <9.0 9.0
LW-04 20658 Rm 507 Right Unitvent Rear <9.0 9.0
LW-05 20658 Rm 615 Unitvent #1 Rear <9.0 9.0
u
LW-06 20658 Rm 404 Unitvent Rear <9.0 9.0
LW-07 20658 Rm 401 East Unitvent Rear <9.0 9.0
LW-08 20658 Rm 401 Left Unitvent Rear <9.0 9.0
LW-09 20658 Rm 401 Right Unitvent Rear <9.0 9.0
FBL-1 20658 Field Blank <9.0 pg 9.0 pg
FBL-2 20658 Field Blank <9.0 pg 9.0 pg
NOTE 1:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 Pg/ft3 Window sills 250 pg/fF,
Window wells 400 pg/ft’, Exterior surfaces 800 pg/ft’.
J NOTES:
Blank units are in pg
LJ
CITY_21MC100_003266283
NYC-WTC_000323242