NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
LJ 104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
n REPORT DATE: 07-17-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers St., NY
SAMPLED BY: Client
SAMPLE DATE 07-16-02
DATE RECEIVED: 07-16-02
DATE ANALYZED: 07-16-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(gg/ft^
W-01 20428 Rm 925 South Side Left Univent (Back Wall) <9.0 9.0
W-02 20428 Rm 925 South Side Right Univent (Back Wall) <9.0 9.0
W-03 20428 Rm 913 South Side Right Univent (Back Wall) 10.1 9.0
W-04 20428 Rm 913 South Side Middle Univent (Back Wall) 11.4 9.0
W-05 20428 Rm 913 South Side Left Univent (Back Wall) <9.0 9.0
W-06 20428 Field Blank <9.0 pg 9.0 pg
W-07 20428 Field Blank <9.0 pg 9.0 pg
NOTE 1:
THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
■il HUD Guidelines for final clearance dust wipe samples: Floor 40 pgTl’, Window sills 250 pg/fF,
Window wells 400 pg/ft’, Exterior surfaces 800 pg/fF.
NOTE 3:
Blank units are in pg
CITY_21MC100_003266227
NYC-WTC_000323187