ATC ASSOCIATES, INC 104 E 25th Street, 10th Floor New York, NY 10010 iS Tel. 212-353-8280 Fax 212-353-8306 SRJ

REPORT DATE: 08-09-02

CLIENT: Taylor Environmental Group, Inc. r1 PROJECT NAME: SCA/Stuyvesant HS 2nd Floor

PROJECT NUMBER: M477-15217/29881

SAMPLED BY: Client

SAMPLE DATE 08-08-02 DATE RECEIVED: 08-09-02 DATE ANALYZED: 08-09-02

SAMPLE MEDIA: Air Samples ANALYSIS REQUIRED: Method NIOSH 7082

ANALYSIS RESULTS

SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION ID NO. CONCENTRATION LIMIT (dg/m") (lig/m’)

AL-01 21025 Rm 250 by Entrance <2.0 2.0

AL-02 21025 Rm 251 by Entrance <2.0 2.0

AL-03 21025 Rm 273 by Entrance <2.0 2.0

BL3 21025 Field Blank <1.5 ng L5 'ng L. J BL4 21025 Field Blank <1.5 ng 1.5 ng

AL-04 21025 In Rm 103 Center <1.1 1.1

AL-05 21025 In Rm 105 by Door <1.1 1.1

AL-06 21025 In Rm 103 Center <1.3 1.3

AL-07 21025 In Rm 105 by Door <1.3 1.3

BLl 21025 Field Blank <1.5 ng 1.5 ng

BL2 21025 Field Blank <1.5 ng 1.5 ng

NOTED THE REPORTING LIMIT (RL) IS 3.0 ng NOTE 2: M At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has established an action level of 30 ng/m’ and a permissible exposure level (PEL) of 50 ng^m’ for personal samples. NOTE 3; Blank units are in ng

CITY_21MC100_003266181

NYC-WTC_000323142

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000323142Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →