NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
Hi
0
i, REPORT DATE: 08-01-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
6th Floor
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
nu SAMPLE DATE
DATE RECEIVED:
08-01-02
08-01-02
DATE ANALYZED: 08-01-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOSH 7082
ANALYSIS RESUI.TS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(pg/m’) (pg/m’)
01 20824 In Library at Doorway <3.6 3.6
n
u
02 20824 Rm 615E at Doorway <3.6 3.6
3.1
03 20824 In Library at Doorway <3.1
04 20824 Rm 615E at Doorway <3.1 3.1
FB-5 20824 Field Blank <1.5 pg 1-5 ug
FB-6 20824 Field Blank <1.5 Mg 1.5 ug
NOTE 1:
THE REPORTING LIMIT (RL) IS 3.0 pg
id NOTE 2:
At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has
established an action level of 30 pg/m’ and a permissible exposure level (PEL) of 50 pg/m’ for personal samples.
NOTE 3:
Blank units are in pg