NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
NYC-WTC_000322244–000322270OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
stringent EPA requirement of particulate matter of 40 ug/m3 (micrograms per cubic meter) is applicable to children and adults with asthma or other respiratory health conditions. The Annual average Standard has been set at 15 ug/m3.
The data presented here has been gathered using EPA’s Federal Reference Method (FRM) and will be used for determining compliance with the health-based standards. The PM-2.5 FRM is a filter based method whereby one 24-hour sample is collected every third day (except at a few daily monitoring locations).
4.01 What is Particulate Matter (PM)
Airborne particulate matter (PM) consists of many different substances suspended in air in the form of particles (solids or liquid droplets) that vary widely in size. The particle mix in most U.S. cities is dominated by fine particles (less than 2.5 microns in diameter PM-2.5)^ produced by combustion including vehicle exhaust and by chemical reactions between gasses such as sulfur dioxide, nitrogen oxides, and volatile organic compounds (VOC’s).
The particle mix also usually contains smaller amounts of coarse dust (between 2.5 and 10 micrometers in diameter).
The fine particles resulting from the collapse of the World Trade Center (WTC) are largely due to the smoke from combustion of fuels and other combustible materials. The coarse dust in the WTC area is largely due to the removal of building debris and rubble. The potential health effects that were addressed to determine the filtration requirements for the New York City schools under study are addressed in the following report sections:
4.02 Health Effects of Dust and Smoke
Dust and smoke may irritate healthy people’s eyes, nose, throat, and lungs, and might cause more serious problems in sensitive populations. Because dust and smoke are mixtures of different chemicals with different sizes, not everyone will experience the same effects. EPA guidelines indicates that most healthy adults and children will recover quickly from short-term dust and smoke exposures and will not suffer long-term consequences and in general, the long-term risk from short-term exposures to dust and smoke is low.
4.03 Sensitive Populations Certain sensitive populations, listed below, are susceptible to more severe symptoms, including cough, phlegm, wheezing, shortness of breath, bronchitis, increased asthma attacks, and aggravation of lung or heart disease. Exposure to fine particles (e.g.
* PM is the abbreviation for Particulate Matter. PM-2.5 is the abbreviation for Particulate Matter with a diameter smaller than 2 1/2 microns, where a micron is one millionth of meter. These particles are known as fine particles and can accumulate deep into lung tissue.
<^\6_R9trom»n9HVAC_R.Cascon«.doc Page 3
CI TY_2 IMC'io 0_009093082
NYC-WTC_000322248
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
22 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
28 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
21 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
17 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
11 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
10 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104673
Report from Consulting & Testing Services, Inc. regarding air quality monitoring at NYU Downtown Hospital in September 2001.
7 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
14 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
10 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
15 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106411
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
11 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289717
Draft screening criteria for WTC health risk assessment; resident and site-worker populations.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000204902
Information page from the EPA regarding fine particulate matter (PM 2.5) air monitoring data and health level of concern guidelines.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similar indexed content
NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similar indexed content
NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
Similar indexed content
NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similar indexed content