NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 414 pages

Ground Zero environmental health schools report

Machine-extracted title · confidence 45%

Document discussing lessons learned in children's environmental health related to Ground Zero sites.

NYC-WTC_000276036–000276449
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

While environmental air sampling results outside of the debris pile and outside of the plume continue to show that levels of dust and other substances are within the levels specified by federal standards. City and State health agencies are communicating with physicians in the community to determine health conditions.

What is fine particulate matter and why is it being monitored?

The explosion at the WTC released ver>' small airborne particles into the air known as "fine particulate matter,” or “PM" for short. Particulate matter comes mostly from the process of combustion (burning). Fires are a source of particulate matter, as is the exhaust from cars, trucks, buses, and other operations that involve the burning of fuel.

Particulate matter ranges in size from very small to larger particles. The most commonly measured sizes are PM 25 and PM 13. PM 25 refers to particles that are 2.5 microns or less in diameter. These particles are extremely small and are therefore more likely to be inhaled deeper info the lungs. PM ,0 refers to particles that include 2.5 microns in size as well particles up to 10 microns in diameter, which, because of their relatively larger size, cannot travel as deep into the lungs. Increased levels of fins particulate matter can cause eye, nose, throat and lung irritation, which can trigger coughing and sneezing. Such exposures may aggravate symptoms for persons with underlying respiratory conditions.

Even prior to September 11, the Nev/ York State Department of Environmental Conservation (NYSDEC) has had continuous (real-time) air particulate monitors (PM 2,5) collecting samples at eleven sites in New York City. These routine monitors are located in each Borough. The data from these monitors are evaluated daily. Additional monitors have been set up to collect particulate data (PM 2 5 and PM 10) in the community near the site. Results from the air monitors are compared to the National Ambient Air Qualify Standard. For PM ,0 the standard is 150 micrograms of particles per cubic meter of air (ug/m3). For PM 2.5, the standard is 65 ug/m3 for the general population. The PM 2.5 standard is 40 ug/m3 for people with respiratory illnesses, individuals with heart problemiS and the elderly or young, since these individuals may be more susceptible to more severe symptoms.

What are the results of the PM 2.S and PMio monitoring?

Testing at the monitoring sites set up both before and after September 11*'’has revealed that, in general, levels office and course Particulate Matter have been within the EPA standards.

Where can I find more information on the WTC-related environmental testing?

Daily WTC-related reports that contain results of sampling for air, water, and dust- including asbestos and Particulate Matter- are posted online at the U.S. Environmental Protection Agency’s website, epa.gov. DEP results are posted atnyc.gov/dep.

January 2002

4

CITY_21MC100_012172974

NYC-WTC_000276129

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276129Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →