WTC sampling method for indoors, asbestos and lead

Machine-extracted title · confidence 60%

Monitoring method outlines micro vacuuming and co-located samples for asbestos and lead.

NYC-WTC_000321914
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies

Analytical Media Sampling Points Sampling Method Proposed Description Analytical Method Proposed Parameters

This is a micro vacuuming method. Three co-located samples will Settled Dust Carpets, fabric furniture or Asbestos ASTM D 6755-95 ASTM D 5755-95 be collected from each location. Porous Soft drapery in areas of activity surfaces (living rooms, family rooms) This is a micro vacuuming method. Three co-located samples will Lead ASTM E 1973-99 SW-846 6010B be collected from each location.

Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)

Lead HUD Appendix 13.1 Wipe Samples SW-846 6010B Horizontal surfaces of Dioxins ASTM D 6661-01 Settled Dust Wipe Samples ASTM GG61-01/SW-846 6290 tables or counters and bare Non-porous floors, ceilings and walls in PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C Hard areas of activity (living surfaces Total Dust HUD Appendix 13.1 Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified) rooms, family rooms) Silica, calcite, HUD Appendix 13.1 Wipe Samples. All parameters will be collected on one wipe. NIOSH 7500 (XRD) gypsum MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300 Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup Practical Quantitation Limit (PQL) method. Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 SW-846 6010B wkgroup PQL

Air pump operated at 2L/min for 8 hours. Pilot Clean-up study only SW-846 8270 (Analytical method with be PAHs NIOSH 5515 for worst case scenarios. modified to achieve the COPC wkgroup PQL Areas of known activity Indoor Air (livinn rooms, family rooms) Ail pump operated at 25umin for 35 hours. I his modification is not Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290 o“iiy for worst cosc sccuanus.

Silica, calcite, Air pump operated at 2.5L/min for 8 hours Io achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) gypsum wkgroup PQL Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling. Bulk samples will be collected from HVAC or AC window type unit PLM NYS 198.1 followed by Asbestos Bulk Sample filters, shaken into a plastic bag and transferred into the sample TEM NYS 198.4 container. (If the volume required is not sufficient for all analyses, the sample Lead Bulk Sample SW-846 601 OB HVAC systems and AC will be analyzed for asbestos only. o units (collection of bulk dust (If the volume required is not sufficient for all analyses, the sample PAHs Bulk Sample SW-846 8270 Bulk Dust sample from the unit air will be analyzed for asbestos only. A filters). Background study (If the volume required is not sufficient for all analyses, the sample I only. Dioxins Bulk Sample SW-846 8290 to will be analyzed for asbestos only.

I Silica, calcite, gypsum Bulk Sample (If the volume required is not sufficient for all analyses, the sample will be analyzed for asbestos only. NIOSH 7500 (XRD) o (If the volume required is not sufficient for all analyses, the sample MMVF Bulk Sample PLM NYS 198.1/EMSL MSD.0300 1° will be analyzed for asbestos only. o o NOTE: " VVipe samples for silica, calcite and gypsum will be collectecl using the HUD Appendix 13.1 method since no standardized method is available. o (JI T ■ to cn

NYC-WTC_000321914

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321914Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC sampling plan and procedures

NYC-WTC_000277652

Plan describing micro vacuuming sampling method and target materials (asbestos, lead, etc.).

Similar indexed content

Compare copies and versions →