NYC 9/11 Public Portal Document
ENVIRON
January 17, 2002
Mr. George Olsen, Esq.
9.
Parent-Teacher Association
Public School 234
292 Greenwich St
New York, NY 10007-1081
Re: Report to Public School 234 Parent-Teachers Association
Dear Mr. Olsen:
The purpose of this letter is to provide the P.S. 234 Parent-Teacher Association with'the results of
ENVIRON’s evaluation of environmental data that was collected in and around the P.S. 234 facility.
The data have been collected by the Board of Education’s consultants, ATC Associates, as well as
the School Construction Authority and its consultants. Aspects of the sampling were performed in
response to recommendations made by ENVIRON on behalf of the P.S. 234 PTA. The sampling
and analysis recommendations made by ENVIRON were based on several inspections of the school
building and grounds, review of previously-collected data at the P.S 234 facility, and an initial
review of publicly-available analytical data collected for ground zero and the areas around ground
zero by the U.S. Environmental Protection Agency, the New York State Department of
Environmental Conservation, the Occupational Safety and Health Administration, and other
agencies.
Details of all the sampling conducted at P.S. 234 are provided on the attached summary. The
sampling results were reviewed by specialists at ENVIRON with expertise in human health risk
assessment. The results of our evaluation of the sampling are summarized below:
• Asbestos: Only trace levels (less than one percent) of asbestos were ever detected in any
samples collected inside the school (and only in samples collected prior to the cleanup of the
school) and the vast majority of samples in the school have shown no detectable asbestos
fibers. Only one debris sample collected from around the school (debris from the roof), was
found to contain asbestos above the regulatory threshold of 1 percent. Extensive cleaning of
the school interior and exterior was conducted, followed by aggressive air monitoring. The
results of several rounds of air testing following the completion of the cleaning operation,
conducted using Transmission Electron Microscopy (TEM), have shown no asbestos fibers
detected in any sample, either inside or outside of the school. Cleanup was also performed in
the playground and on the roof to remove debris that contained trace levels of asbestos and
follow-up sampling has not detected any asbestos. Further asbestos monitoring inside and
outside the school is part of the on-going monitoring program, as discussed below.