Air sampling locations, Feb 11, 2002

Machine-extracted title · confidence 39%

NYC/ER asbestos results; all below TEM AHERA; dioxin and particulate notes included.

NYC-WTC_000321316–000321318
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Jessica Leighton - RA sitrepO2-11 .wpd Page:^

o Instruments operated 8 hours. o Station L had an average of 26.83 ug/m’ with a maximum reading of 383.3 ug/m/ o Station N had an average 26.14 ug/m^ with a maximum reading of 210.27 ug/m\ o Station R had an average 26.58 ug/m’ with a maximum reading of 247.03 ug/m\

NYC / ER (Feb 9) - Particulate Monitoring (Dataram)

o Particulate levels noted at three locations (Stations L, N, and R) were below the OSHA TWA. o Instruments operated approximately 8 hours. o Station L had an average of 23.56 ug/m’ with a maximum reading of 60.66 ug/m\ o Station N had an average 20.92 ug/m’ with a maximum reading of 52.81 ug/m\ o Station R had an average 20.49 ug/m’ with a maximum reading of 103.14 ug/m\

NYC / ER (Feb 10) - Particulate Monitoring (Dataram)

o Particulate levels noted at three locations (Stations L, N, and R) were below the OSHA TWA. o Instruments operated approximately 8 hours. o Station L had an average of 31.95 ug/m" with a maximum reading of 108.68 ug/m\ o Station N had an average 41.10 ug/m’ with a maximum reading of 369.16 ug/m\ o Station R had an average 33.01 ug/m^ with a maximum reading of 77.83 ug/m\

NYC / ER (Feb 7) - Volatile Organics (Mobile Laboratory)

o Numerous compounds were identified above the detection limit (20 ppbv) at the South Tower in a ground level plume sample. o VOCs were not detected in any of the three other samples collected (Washing Tent, Austin Tobin Plaza, and North Tower).

NYC / ER (Feb 8) - Volatile Organics (Mobile Laboratory)

o Numerous compounds were identified above the detection limit (20 ppbv) at the South Tower in a ground level plume sample. o VOCs were not detected in any of the three other samples collected (Washing Tent, Austin Tobin Plaza, and North Tower).

NYC / ER (Feb 9) - Volatile Organics (Mobile Laboratory)

o Black smoke Irom an unknown source identified from a 4-inch subsurface pipe at the B-3 level of the Austin Tobin garage.

CITY_21MC100_000938694 NYC-WTC_000321317

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321317Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321324

EPA air sampling results for NYC/ER asbestos locations, Feb 3–12, 2002.

Similar indexed content

NYC-WTC_000321253

Jan 11–12 2002 asbestos sampling; access issues for Location T; low sample volumes noted.

Similar indexed content

Compare copies and versions →