NYC 9/11 Public Portal Document
410.90 ug/m^
NYC / ER (Mar 16) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, and R) were below the
OSHA TWA.
o Instrument at Location L was weather-proofed and operated approximately 8
hours
o Instruments at Locations N and R operated approximately 1 hour due to weather
conditions.
o Station L had an average of 79.34 ug/m^ with a maximum reading of 231.92
ug/m^
o Station N had an average of 108.91 ug/m’with a maximum reading of
152.22 ug/m’.
o Station R had an average of 114.74 ug/m’ with a maximum reading of
162.03 ug/m’.
NYC / ER (Mar 17) - Particulate Monitoring (Dataram)
o Particulate levels noted at two locations (Stations N and R) were below the OSHA
TWA.
o Particulate measurements were not conducted at Station L due to an equipment
malfunction.
o Instruments operated approximately 8 hours.
o Station N had an average of 16.21 ug/m’with a maximum reading of
107.86 ug/m’.
o Station R had an average of 17.79 ug/m’ with a maximum reading of
107.48 ug/m’.
NYC / ER (Mar 14) - Volatile Organics (Mobile Laboratory)
o Several volatile organic compounds were detected above the detection limit (20
ppbv) in a sample taken at the Austin Tobin Plaza location.
o Aside from one volatile organic compound detected at the Washing Tent above the
detection limit (20 ppbv), no other compounds were detected at the other locations
(North and South Towers) that were sampled.
o Data is not attached electronically.
NYC / ER (Mar 15) - Volatile Organics (Mobile Laboratory)
o Aside from one volatile organic compound detected above the detection limit
(20 ppbv), at the ground surface of both the North and South Tower locations, no
other compounds were detected at the other locations (Washing Tent and Austin
Tobin Plaza) that were sampled.
NYC / ER (Mar 16) - Volatile Organics (Mobile Laboratory)
CITY_21MC100_002417035
NYC-WTC_000287265
OCR can misread numbers and units. Confirm readings against the page image before using them.