NYC 9/11 Public Portal Document
' Jessica Leighton - RA_sitrepO1 -28.wpd 7^
/
Page lj
U.S. Environmental Protection Agency (m’M’M’.qpa.gov)
Sampling Situation Report
Monday, January 28, 2002
Fixed Ambient Air Sampling Locations (Asbestos)
NYC / ER (Jan 23, 1200 - 2359 hrs)
o All 21 samples analyzed were below the TEM AHERA standard.
o 1 sample (Location E) was not collected due to an equipment malfunction.
NYC / ER (Jan 24, 0001 - 1200 hrs)
o All 21 samples analyzed were below the TEM AHERA standard.
o 2 samples (Location I) was not collected due to an equipment malfunction.
Landfill Ambient Air Sampling Locations
Fresh Kills (Jan 24 - 27) - Particulate Monitoring (Dataram)
o No particulate measurements were conducted during this period due to inoperative
equipment.
Ambient Air Sampling Locations
NYC / ER (Dec 11) - Isocyanates
o 12 samples collected for confirmatory laboratory analysis of previously conducted
field screening measurements.
o Locations monitored: North Tower (northwest comer), West/Liberty Sts., and
Locations A, B, C, D, E, P, R, S, 3B from the fixed ambient air sampling stations.
o Sampling period consisted of a 15-minute grab at each location.
o All 12 samples did not detect any isocyanates.
o Field screening conducted previously at the two work-zone locations referenced
above detected low levels of HDI and TDI (at or just above the instrument detection
limits).
NYC / ER (Dec 19) - Isocyanates
o 12 samples collected for confirmatory laboratory analysis of previously conducted
field screening measurements.
o Locations monitored: North Tower, Vista Hotel, and Locations A, B, C, D, E, P, R, S,
3B from the fixed ambient air sampling stations.
CITY_21MC100_000938683
NYC-WTC_000321306
OCR can misread numbers and units. Confirm readings against the page image before using them.