Air Sampling, NYC/ER, Nov 10–12 2001

Machine-extracted title · confidence 38%

Asbestos air sampling results; some exceedances at indoor/perimeter locations.

NYC-WTC_000321165–000321167
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency (www.epa.gov) Air / Bulk / Wipe / Water Sampling Situation Report Wednesday, November 14, 2001

Fixed Ambient Air Sampling Locations (Asbestos) NYC / ER (Nov 10, 1200 - 2359 hrs) o All 20 samples analyzed were below the TEM AHER A standard.

NYC / ER (Nov 11, 0001 - 1200 hrs) o All 20 samples analyzed were below the TEM AHER A standard.

Landfill Ambient Air Sampling Locations Fresh Kills (Nov 11, 0656 - 1946) - Asbestos o 2 of 14 samples analyzed were above the TEM AHER A standard. o Exceedances of the TEM AHER A standard occurred at “ Sift” Location #9A (120 S/mm^) and indoor “Wash” Location #12A (195.56 S/mm*). o 5 samples (“Sift” Location #10A, “Wash” Location #11, perimeter station at “Wash” Location #12B, Mess “Tent” Location #15, and Supply “Tent” Location #16) were not analyzed due to particulate overloading.

Fresh Kills (Nov 11) - Particulate Monitoring (Dataram )

o Increased daily average readings noted at Perim eter Location #8. o Reduced dataram availability (5 stations).

Ambient Air Sampling Locations

• NYC / ER (Nov 12) - Particulate Monitoring (PMj 5) o Pace University (Site 1) - 24-hr average concentration for this period was 10.24 ug/m\ o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 8.18 ug/m^. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 6.7]ug/m\ o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m’).

NYC / ER (Nov 9) - Particulate Monitoring (Dataram ) o Particulate levels noted at three locations (Stations L, N, R ) were below the OSHA TWA. o Instruments operated approximately 8 hours. o Station L values ranged from 0 to 245 ug/m’ with an average of 12.1 ug/m\ o Station N values ranged from 0 to 860 ug/m^ with an average of 2.7 ug/m\ o Station R values ranged from 0 to 130 ug/m^ with an average of 11.2 ug/m\

CITY_21MC100_003051321

NYC-WTC_000321165

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321165Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321195

Asbestos air sampling results at NYC/ER and Fresh Kills; notes on pending results and malfunctions.

Similar indexed content

NYC-WTC_000321153

Errata and results for asbestos sampling; some data revised.

Similar indexed content

Compare copies and versions →