Air Sampling, NYC/ER, Nov 6–9 2001

Machine-extracted title · confidence 38%

Errata and results for asbestos sampling; some data revised.

NYC-WTC_000321153–000321156
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency (ivww’.e/jn.gov) Air / Bulk / Wipe / Water Sampling Situation Report Tuesday, November 13, 2001

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Nov 6, 0001 - 1200 hrs) o Errata: Previously reported on Friday, November 9 that PCM results for Locations I and D should be considered suspect and are undergoing further evaluation. Attached is a revised data table with corrected results. All other analytical results remain the same. NYC / ER (Nov 9, 1200 - 2359 hrs) o All 20 samples analyzed were below the TEM AHER A standard.

NYC / ER (Nov 10, 0001 - 1200 hrs) o All 19 samples analyzed were below the TEM AHERA standard. o 1 locations (S) was not sampled.

NJ / ER (Nov 5)

o All 5 samples analyzed (which includes a duplicate) were below the TEM AHER A standard. Landfill Ambient Air Sampling Locations Fresh Kills (Nov 7, 1953 - Nov 8, 0655) - Asbestos o Errata: Previously reported on Saturday, November 10 that all 19 samples analyzed were above the TEM AHERA standard. Should actually read that all 18 samples analyzed were below the TEM AHERA standard. o 1 location (“Barge” Location #13) was not sampled. o Data not attached.

Fresh Kills (Nov 8, 1900 - Nov 9, 0828) - Asbestos o Errata: Previously reported on Monday, November 12 that all 18 samples analyzed were below the TEM AHERA standard. Should actually read that all 17 samples analyzed were below the TEM AHERA standard. One additional location (“Wash” Location #12A) was not analyzed due to overloading of particulates. o 1 location (Supply “Tent” Location #16) was not analyzed due to overloading of particulates o Data not attached. Fresh Kills (Nov 9, 1919 - Nov 10, 0809) - Asbestos o All 19 samples were below the TEM AHERA standard.

CITY_21MC100_003051316

NYC-WTC_000321153

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321153Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Air sampling locations, Oct 2001 · Box unavailable

NYC-WTC_000321276

NYC/ER and NJ/ER asbestos monitoring; some locations not sampled due to pump/malfunction; one exceedance at indoor wash location.

7 shared non-person entities · 1 shared topics · similarity 0.973

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321165

Asbestos air sampling results; some exceedances at indoor/perimeter locations.

Similar indexed content

NYC-WTC_000321168

Asbestos sampling results; routine monitoring with mostly below-standard values.

Similar indexed content

Compare copies and versions →