NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency (w’M’M’.epa.^ov) Air / Bulk / Wipe / Water Sampling Situation Report Wednesday, November 7, 2001

Fixed Ambient Air Sampling Locations (Asbestos) NYC / ER (Nov 3, 1201 - 2400 hrs) o All 20 samples analyzed were below the TEM AHER A standard.

NYC / ER (Nov 4, 0001 - 1200 hrs)

o All 20 samples analyzed were below the TEM AHER A standard.

Landfill Ambient Air Sampling Locations Fresh Kills (Nov 3, 0655 - 1928) - Asbestos o All 18 samples analyzed were below the TEM AHER A standard. o 1 sample (“Sift” Location #10B) was not analyzed due to particulate overloading. Fresh Kills (Nov 3, 1709 - Nov 4, 0744) - Asbestos

o All 18 samples analyzed were below the TEM AHER A standard. o 1 location (“Barge” Location # 13) was not sampled due to a broken pum p.

Fresh Kills (Nov 4, 0657 - 1927) - Asbestos

o All 19 samples analyzed were below the TEM AHER A standard.

Fresh Kills (Nov 4, 1837 - Nov 5, 0657) - Asbestos o All 17 samples analyzed were below the TEM AHER A standard. o 1 locations (“Barge” Location #13) was not sampled due to a broken pump. o 1 location (perimeter station at “Wash” Location #12B) had a pump failure (results deemed invalid).

Ambient Air Sampling Locations

NYC / ER (Nov 4) - Particulate Monitoring (Dataram ) o Particulate levels noted at thr ee locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 716 hours. o Station L values ranged from 0.0 to 62.5 ug/m^ with an average of 17.3 ug/m^. o Station N values ranged from 0.0 to 56.0 ug/m^ with an average of 10.5 ug/m\ o Station R values ranged from 0.0 to 56.0 ug/m^ with an average of 13.3 ug/m\ o Note: Dataram readings for Nov 2™* were determined to be unuseable. o Note: Dataram readings not collected on N ov 3’^'* due to rain.

CITY_21MC100_002458749

NYC-WTC_000321147

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321147Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321157

Asbestos sampling results; several locations below standard; one exceedance noted.

Similar indexed content

EPA air sampling, Oct 20, 2001

NYC-WTC_000287603

Resubmittal of asbestos results with additional data; most samples below AHERA standard.

Similar indexed content

EPA air sampling, Oct 17/18 2001

NYC-WTC_000301843

Particulate and asbestos sampling notes for NYC/ER and Fresh Kills; some exceedances noted.

Similar indexed content

Compare copies and versions →