Daily Environmental Monitoring Summary, Oct 24 2001

Machine-extracted title · confidence 38%

EPA daily environmental monitoring summary for air, dust, water from WTC site.

NYC-WTC_000321143–000321144
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

□CT-26-2001 14:43 ENUIROMENTPL DISEfiSE PREU 212 788 4289 P.04/04

Park. All 24-hour average values were below the National Ambient Air Quality Standards (65 ug/m3) for all stations.

Particulate Monitoring - EPA used portable monitors to collect samples on October 23 in the following areas, which are also the locations of Fixed Air Monitors: L (north east side of Stuyvesant High), R (north west side of Stuyvesant High School), and N (South side of Pier 25). All readings were all below the OSHA time-weighted average permissible level for particulates.

Silicates - Ten samples collected on October 8 showed no detectable levels of silicates.

Dioxin - Ten samples were collected in the restricted work area near ground zero on October 8 and analyzed for dioxin. Four of the samples showed results above the level at which EPA would take some type of action to reduce people's exposure. This action level, however, is based on a 30-year exposure scenario. None of the ten samples were above the EPA's action level adjusted to a 1-year exposure duration. These levels do not pose a short-term health affect but should be monitored if they persist for a longer period of time.

Direct Air Readings - Using portable monitors, direct air readings were taken in and around ground zero on October 23. No significant readings, including those for carbon monoxide, were detected.

Bulk/Dust Dioxin - Two dust samples were collected on October 8 from rooftops in the vicinity of the former World Trade Center. Both samples were below the EPA residential cleanup goal of 1 part per billion.

Latest Available Daily Environmental Monitoring Summary

Resources on the World Wide Web:

US Department of Labor's Occupational Safety and Health Administration

New York City Department of Health US Department of Health and Human Services New York State Emergency Management Office MBBBB

EPA information about the events of September 11

EPA Home [ Privacy and Security Notice | Contact Us Last Updated; Thursday, October 25 2001 06:35:12 U RL: http:z/www.epa.gov/epahonie/wtc/epa-osha102401 .htm

2of2 10/26/01 1'49PM TOTAL P.04

CITY_21MC100_0Ci09 48 4 77 NYC-WTC_000321144

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321144Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000281811

EPA daily environmental monitoring summary for air, dust, water around WTC site.

Similar indexed content

NYC-WTC_000321145

EPA daily environmental monitoring summary for 9-11 response and monitoring data.

Similar indexed content

NYC-WTC_000287170

EPA daily monitoring data for the World Trade Center center site and surroundings, Oct 12, 2001.

Similar indexed content

NYC-WTC_000287168

EPA daily summary of monitoring data for the World Trade Center site area.

Similar indexed content

Compare copies and versions →