NYC Response Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Time: 09/29/01 0700 to 1900

PCMbyNIOSH 7400 TEM by NIOSH 7402 TEM AHERA) Sampling Sampling Sample f/mm’ f/cc AF/NAF Adjusted Structures (#) S/mm^ S~f/cc* Date Sample No. Location Volume Matrix TEM f/cc <5u >5|j

9/29/01 01644 #1 325 Air <7.0 <0.008 0/0 <0.008 0 0 <8.00 <0.0095 9/29/01 01645 #2 645 Air <7.0 <0.004 0/2 <0.004 0 0 <8.00 <0.0048 9/29/01 01646 #3 641 Air <7.0 <0.004 0/2 <0.004 0 0 <8.00 <0.0048 9/29/01 01647 #4 647 Air <7.0 <0.004 0/1 <0.004 0 0 <8.00 <0.0048 9/29/01 01648 #5 647 Air <7.0 <0.004 0/1 <0.004 0 0 <8.00 <0.0048 9/29/01 01649 #6 439 Air <7.0 <0.006 0/0 <0.006 0 0 <8.00 <0.0070 9/29/01 01650 #7 650 Air <7.0 <0.004 0/0 <0.004 0 1 8 0.0047 9/29/01 23660 #8 644 Air <7.0 <0.004 0/1 <0.004 0 0 <8.00 <0.0048 9/29/01 23661 #9A 635 Air <7.0 <0.004 0/2 <0.004 0 0 <8.00 <0.0049 9/29/01 23662 #9B 646 Air <7.0 <0.004 0/2 <0.004 3 0 24 0.0143 9/29/01 23663 #10 675 Air <7.0 <0.004 0/3 <0.004 0 0 <8.00 <0.0046 coc# 04012 NS: Not sampled AF/ANF: Asbestos fibers/Non asbestos fibers Sample volume is below recommended limit of the method: ‘Structure (S) roughly equivalent to fiber (f) NA: not analyzed due to overloading of particulates

NIOSH 7400: Fiber Analysis of Ar samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 NIOSH 7402: Asbestos Analysis of Air samples by Transmission Electron Microscopy Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm\ volume 1200 L, for 25 mm filter (TEM)

ERT: 10/01/01 9.50 AM

o H

to

s o o 1° o to Ui (_n co FK-09-29-01.xls to co

NYC-WTC_000321063

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321063Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →