NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 25 pages

World Trade Center Response Air Monitoring Overview, EPA/NYSDOH, 2001

Machine-extracted title · confidence 40%

World Trade Center response air monitoring data overview describing EPA data collection.

NYC-WTC_000321003–000321027
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

m m S «

z PM 2.5 Air Monitoring Data Summary for NYC WTC Sampling 3 a. 5- CD CL o <s2 S i 3 1.02% 0.04% Totals (for sampling through 05/15/02, In ug/m3) in

I S’ a •• Screening Levels: 40 & 65 Total Samples: 91,305 Samples Below Screening Level (40ug/m3): 90,370 % Below (40 ug/m3): 98.98 11 ■D 5. Samples Below Screening Level (65ug/m3): 91,272 □ % Below (65 ug/m3): 99.96 S o' Samples Above Screening Level (40 ug/m3): 935 CD S zr g % Above (40 ug/m3): 1.02 cu ® Samples Above Screening Level (65 ug/m3): 33.00 % Above (65 ug/m3): 0.04 § m Minimum Value: -50.04 98.98% 99.96% Maximum Value: 165.63 Q Samples Below Screening Level O Samples Below Screening Level Average: 13.47 2 (40ug/m3) (65ug/m3) II ■ Samples Above Screening Level ■ Samples /\bove Screening Level 8 3 (40 ug/m3) (65 ug/m3) 3 o z o ■o These values show how much fine c CT particulate matter (particles less than P’ X 2.5 micrometers in diameter) the New II □ York State Department of o Environmental Conservation has measured in the air at this site, on the o □ dates and times shown. Daily o-» summaries of these measurements qT (http://www.epa.qov/wtc/data summary. O' lew Jerse htm) and how they compare to the Q 0? screening level for public health are also 5’ available. co

I’ ' Airborne particles like smoke and dust i Quaens are solids and liquid droplets of different / .' sizes suspended in the air. EPA sets the screening level to caution sensitive groups, including children, the elderly,

Y, and people with heart or lung disease. For fine particles, that level is 40 ug/m3* (the mass of fine particles in micrograms (a millionth of a gram) in a Brooklyn cubic meter of air) for 24-hour average exposure. This level is based on EPA's Air Quality Index. Above this level, we recommend that sensitive groups reduce their exposure. Shorter term peaks are also of potential concern for sensitive groups. The screening level for the general population is 65 ug/m3 over a 24 hour period. Most healthy adults and children are expected to recover quickly from any symptoms of short-term exposure like coughing, wheezing, or eye and throat irritation. EPA expects the long-term risk from these short-term exposures to be low.

There are two methods for measuring particulate matter (PM) being used at the monitoring sites presented on the EPA website.

For additional information on World Trade Center Monitoring, see httD://www.eDa.qov/wte/ Created on 6/4/02 O) 8

CITY_21MC100_002458698

NYC-WTC_000321010

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321010Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →