NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 25 pages

World Trade Center Response Air Monitoring Overview, EPA/NYSDOH, 2001

Machine-extracted title · confidence 40%

World Trade Center response air monitoring data overview describing EPA data collection.

NYC-WTC_000321003–000321027
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Air Monitoring Data Summary for Regional WTC Sampling

0.12% Totals (for sampling through 05/07/02, in s/mm2) Screening Level: 70 Total Samples: 1668 Samples Below Screening Level: 1666 % Below: 99.88% Samples Above Screening Level: 2 % Above: 0.12% Minimum Value: Not Detected Maximum Value: 104.99 Average: 14.22 B Samples Below Screening Level 99.88% B Samples Above Screening Level

In evaluating data from the World Trade Center and the surrounding areas, EPA ' Bronx . is using a protective standard under I® AHERA, the Asbestos Hazard Emergency Response Act, to evaluate the risk from asbestos in the outdoor and indoor air. This is a very stringent standard that is used to determine whether children may re-enter a school building after asbestos has been 3 removed or abated. It is based on assumptions of long-term exposure. EPA has chosen to use this standard because it is the most stringent and protective, even though it is unlikely that the public will be exposed to asbestos from the ) 8r««Myn World Trade Center site for extended , Ctgo Linden periods of time. FMC itatsn Island To determine asbestos levels, air filters are collected from monitoring equipment through which air in the school building has passed and viewed through a microscope. The number of structures - material that has asbestos fibers on or in it - is then counted. The measurements must be 70 or fewer structures per square millimeter before children are allowed inside.

There is also a federal standard for asbestos exposure under OSHA, the Occupational Safety and Health Act, which is used to protect workers on-the-job. The standard is .1 fiber per cubic centimeter averaged over an eight-hour day. To be as protective as possible, EPA is using the school re-entry standard in tests around the World Trade Center.

Levels above 70 structures per square millimeter do NOT imply an immediate health threat. Asbestos exposure becomes a health concern when high concentrations of asbestos fibers are inhaled over a long period. Illness is very unlikely to result from a single, high-level exposure, or from a short period of exposure to lower levels.

For additional information on World Trade Center Monitoring, see http://www.eDa.aov/wtc/ Created on 6/4/02 7

CITY_21MC100_002458697

NYC-WTC_000321009

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321009Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →