NYC-WTC_000320945
PM 10 monitoring data summary for NYC WTC through 02/05/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗PM10 monitoring totals, levels of concern, and explanatory notes for NYC WTC sampling.
NYC-WTC_000320918
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
PM 10 Air Monitoring Data Summary for NYC WTC Sampling //• Totals (for sampling through 02/05/02, in ug/m3) Total Samples_______________ 4210 Samples above Level of Concern 4 Samples below Level of Concern 4206 Percent Above 150 ug/m3_____ 0.10 Maximum Value (09/13/01 at 316.57 Albany St.)__________________ Minimum___________________ -3.73 Level of Concern_____________ 150 Average 27.58
0% Particles in the air can be different sizes; when smaller than 10 micrometers in diameter, they can be inhaled into the lungs. These particles, also called "PM10," include both fine smoke and coarse dust.*** EPA sets ■ Samp Ips ahnvR the level of concern for PM 10 to caution sensitive Le’-el of Coiice n groups, including children, the elderly, and people with heart or lung disease, about exposures to coarse dust E Samples jelow Le'fel of Concern particles. The PM 10 level of concern for sensitive groups is 150 ug/m3’* for 24-hour average exposure. This level is based on EPA's Air Quality Index. Above this level, we recommend that sensitive groups reduce 100% their exposure. Most healthy adults, children and the elderly are expected to recover quickly from any symptoms of short-term exposure like coughing. wheezing, or eye or throat irritation. EPA expects the long-term risks from these short-term exposures to be low.
There are two methods for measuring particulate matter (PM) being used at the monitoring sites presented on the EPA website.
The filter method is based on ambient air being drawn through a filter which traps particles. This provides a 24-hour integrated sample. After the sample is taken, the filter is collected, weighed in a laboratory, and recorded by laboratory staff. This is the method that is being used for PM10 monitoring at the Park Row, Borough of Manhattan Community College, and Coast Guard sites.
The continuous method is based on ambient air being drawn into a chamber to be analyzed mechanically and the recorded electronically. We have installed continuous monitors for PM 2.5 at all of the sites in lower Manhattan. We also have continuous monitors for PM 10 at the Albany Street and Wall Street sites.
The primary difference between filter and continuous methods is that the continuous monitors report hourly-average concentrations and a daily average of the 24 one-hour averages, while the filter-based monitors provide one 24-hour average concentration.
CITY_21MC100_002458606
NYC-WTC_000320918
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000320945
PM 10 monitoring data summary for NYC WTC through 02/05/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320953
PM10 air monitoring data summary for NYC WTC through 02/05/02, with total samples and level-of-concern values.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320907
PM10 sampling totals, levels above/below concern, and site details for NYC WTC area.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320979
PM10 air monitoring data summary for NYC WTC through 02/05/02.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199704
Summary of PM10 air monitoring data for the World Trade Center site through February 5, 2002, including sample counts and levels of concern.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320999
PM10 air monitoring data summary with totals, levels of concern and average value.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353721
PM10 summary: counts, levels of concern, and sample results.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279321
PM10 air monitoring data summary for NYC WTC sampling through Feb 5, 2002.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320928
PM10 totals, level-of-concern values, and explanatory notes for NYC WTC sampling.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199698
Summary of PM10 air monitoring data for the World Trade Center site through February 5, 2002, including sample counts and levels of concern.
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320989
PM10 air monitoring data summary for NYC WTC site with sample counts and exceedance details.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320971
PM10 air monitoring data summary for NYC WTC through 02/05/02.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000320945
PM 10 monitoring data summary for NYC WTC through 02/05/02.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321939
PM2.5 data summary with totals, percent above concern levels, and context notes.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320953
PM10 air monitoring data summary for NYC WTC through 02/05/02, with total samples and level-of-concern values.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000204899
Summary of fine particulate matter (PM 2.5) air monitoring data for the NYC World Trade Center area through February 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243046
Asbestos air data summary around WTC site through 01/29/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320907
PM10 sampling totals, levels above/below concern, and site details for NYC WTC area.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
PM 10 monitoring data summary for NYC WTC through 02/05/02.
Similar indexed content
PM10 air monitoring data summary for NYC WTC through 02/05/02, with total samples and level-of-concern values.
Similar indexed content
NYC-WTC_000320907
PM10 sampling totals, levels above/below concern, and site details for NYC WTC area.
Similar indexed content
PM10 air monitoring data summary for NYC WTC through 02/05/02.
Similar indexed content
Summary of PM10 air monitoring data for the World Trade Center site through February 5, 2002, including sample counts and levels of concern.
Similar indexed content