NYC 9/11 Public Portal Document
PM 10 Air Monitoring Data Summary for NYC WTC
r
Sampling
J; ?
Totals (for sampling through 02/05/02, in ug/m3)
Total Samples_______________ 4210
Samples above Level of Concern 4
Samples below Level of Concern 4206 z;
Percent Above 150 ug/m3______ 0.10
Maximum Value (09/13/01 at 316.57
Albany St.)__________________
Minimum___________________ -3.73
Level of Concern_____________ 150
Average 27.58
0% Particles in the air can be different sizes; when smaller
than 10 micrometers in diameter, they can be inhaled
into the lungs. These particles, also called "PM10,"
include both fine smoke and coarse dust.*** EPA sets
■ Ramplps ?hnvR the level of concern for PM 10 to caution sensitive
Le’-el ofConce n groups, including children, the elderly, and people with
heart or lung disease, about exposures to coarse dust
K Samples jelow
Level of Cotice'n particles. The PM10 level of concern for sensitive
groups is 150 ug/m3** for 24-hour average exposure.
This level is based on EPA's Air Quality Index. Above
this level, we recommend that sensitive groups reduce
100% their exposure. Most healthy adults, children and the
elderly are expected to recover quickly from any
symptoms of short-term exposure like coughing.
wheezing, or eye or throat irritation. EPA expects the long-term risks from these short-term exposures to
be low.
There are two methods for measuring particulate matter (PM) being used at the monitoring sites
presented on the EPA website.
The filter method is based on ambient air being drawn through a filter which traps particles. This provides
a 24-hour integrated sample. After the sample is taken, the filter is collected, weighed in a laboratory, and
recorded by laboratory staff. This is the method that is being used for PM10 monitoring at the Park Row,
Borough of Manhattan Community College, and Coast Guard sites.
The continuous method is based on ambient air being drawn into a chamber to be analyzed mechanically
and the recorded electronically. We have installed continuous monitors for PM 2.5 at all of the sites in
lower Manhattan. We also have continuous monitors for PM 10 at the Albany Street and Wall Street sites.
The primary difference between filter and continuous methods is that the continuous monitors report
hourly-average concentrations and a daily average of the 24 one-hour averages, while the filter-based
monitors provide one 24-hour average concentration.
CITY_21MC100_002458598
NYC-WTC_000320907
OCR can misread numbers and units. Confirm readings against the page image before using them.