NYSDOL sampling summary, WTC site, May 2002

Machine-extracted title · confidence 42%

NYS DOH CEH summary of personal exposure samples; results continue below PEL for asbestos by PCM/TEM.

NYC-WTC_000320747–000320748
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Jessica Leighton - Cover-sample summary 5-2.wpd PageJ]

Surface wipe samples in some of the FDNY’s response vehicles were taken to assist the department with an evaluation of contamination of vehicles which had responded to the WTC site during the first few days of the disaster. These results are included in the data spreadsheet.

Volatile organics All personal sampling results have been well below PESH limits for 32 samples collected for volatile organics. These samples included analyses for the following; acetone, benzene, ethyl benzene, butyl alcohol, isopropyl alcohol, naphtha, styrene, toluene, and xylene.

Acid gases Exposures to acid gases such as hydrogen bromide, hydrogen chloride, hydrogen cyanide, and hydrogen fluoride were all below the detection limit. For sulfuric acid, the highest exposure found was in mid October and was at a level of 0.48 mg/m3, less than half of the limit of 1 mg/m3

PCBs The two personal exposure samples for PCBs on workers monitoring the debris pile had results which were less than the detection limits.

Mercury All 43 personal air samples for mercury have had results which were less than the detection limit. Out of 22 wipe samples for mercury on FDNY vehicles, 21 were below the detection limit and the only positive result was a trace amount of 0.37 ug/100 cm2

Noise Personal monitoring for noise exposure on public employees did not reveal any exposures above the action level 85 dBA. The highest exposure recorded was 83.6 dBA as an 8 hour time weighted average.

Total dust Of 53 personal samples were collected for total dust, only two were above the PEL of 15 mg/ra3. These two samples were taken on workers actively looking through the debris and they were wearing respirators.

Respirable dust There have been 34 personal samples for respirable dust collected . None of the samples have approached the PEL of 5 mg/m3.

CITY_21MC100_006741396

NYC-WTC_000320748

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320748Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Sampling summary, 2/13/2002, DEP

NYC-WTC_000342461

State and local safety sampling summary of personal exposure at WTC site through 1/30/2002.

Similar indexed content

Compare copies and versions →