NYC 9/11 Public Portal Document
I Jessica Leighton - Sample summary-12-11 to 12-30.wpd f^lJ
New York State Department of Labor
Division of Safety and Health
Sampling Summary as of 1/8/2002
Personal exposure sampling has been performed on numerous employees working on and
around the WTC site. This has included firefighters, police officers, state troopers, conections
officers, police detectives, and sanitation workers. The New York State Department of Labor has
to date collected over 250 personal exposure samples on public employees working at the site
with over 1300 analyses performed. The sampling summary below is for activity from 12/11/01
to 12/30/2001 and includes results of 57 personal samples and approximately 200 analyses.
Asbestos The personal samples for asbestos continued to be below the PESH PEL of
0.1 fibers per cubic centimeter with the highest reading of 0.05 fibers per cubic
centimeter.
Carbon Monoxide Results have ranged from 0 to 4 ppm as a time weighted average over the
last few weeks, well below the PESH PEL of 35 ppm. Peak measurements reached did
reach up to 97 ppm, but were of very short duration and did not approach the ceiling limit
of 200 ppm over a five minute period.
Metals Personal samples collected show all exposures to be well below the PESH
PELs. Metals analyzed included lead, copper, manganese, molybdenum,
magnesium, cadmium, nickel, iron, aluminum, zinc, and cobalt.
Mercury Personal sampling for mercury during the last two weeks of December on
public employees participating in search and recovery operations showed all
exposures to be below detection limits
Noise Exposure samples for noise did not reveal any exposures at or above the
PEL of 90 dBA. The highest sample did show an exposure of 83.6 dBA
over a sample period of 468 minutes. This is close to the level which
requires the establishment of a hearing conservation program (85 dBA
over 8 hours), especially in light of the fact that the employees sampled
typically worked 12 hours per day which has the effect of lowering the
action level.
Volatile organics All personal sampling results have been well below PESH limits for
benzene, acetone, isopropyl alcohol, naphtha, petroleum distillates, and toluene.
CITY_21MC100_006741394