NYC 9/11 Public Portal Document
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees at the truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. SO2 personal and area
results were found to be below OSHA limits.
Metals: OSHA has taken approximately 685 air samples to monitor worker exposures to dusts,
fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium,
cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium,
magnesium, and arsenic. Results from these samples are generally well belowthe applicable
OSHA limits. However, torch cutting and burning structural steel at the rubble pile have
resulted in instances of overexposures as follows: copper (10); iron oxide (21); lead (12);
and cadmium (2). Accordingly, OSHA is recommending that workers engaged in these
operations wear appropriate respiratory protection.
Mercury OSHA has taken SI air samples for inorganic mercury. Results for 74 of those air samples
have been received and no mercury was detected. Also, 37 bulk samples previously
collected from rubble were re-analyzed for mercury. None was detected.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with
particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken 15 dioxin samples in the plume over hot spots in (and around the
perimeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than
those found directly over the pile. To date, only one sample taken on the rubble pile
showed dioxin levels which exceeded background levels. Dioxins are considered
collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shown the presence
of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons:
anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have
identified seven samples which reached or exceeded OSHA’s coal tar pitch volatile PEL
of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler
operators. OSHA continues to strongly recommend the use of respiratory protection when
working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken 105 samples for Freon R-22 (chlorodiflouromethane). The majority of
sample results received to date show no detectable airborne levels. During operations
involving Freon removal from the auxiliary chiller that started on 12/5/01, direct reading
instruments used by the entrants revealed readings ranging from 100 ppm to one peak near
a leaky valve of 500 ppm. SCBA tanks were and are being worn by workers, and masks
are to be worn only when direct reading instruments reveal 850 ppm Freon and/or less than
20.4% Oxygen. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL
for Freon is lOOOppm..) In response to information about exposure to the decomposition
by-products of Freon R-22 used in the air conditioning systems of WTC towers, sampling
for hydrofluoric acid (HF) had been conducted. Results for HF sampling show no
detectable levels. Sample results for phosgene to date also show no detectable levels.
Page 2 of 2
CITY_21MC1OO_OO6741388
NYC-WTC_000320741
OCR can misread numbers and units. Confirm readings against the page image before using them.