Ambient and Indoor Sampling for Public Health Evaluations of Residential Areas Near World Trade Center, New York, New York (November 4 - December 11, 2001)

Results were compared to dust and air levels found in homes located in "non-impacted" areas and to indoor asbestos standards. At each sampled building, attempts were made to sample in a common area, two residences, and an adjacent outdoor location.

Dust: If PLM was less than 1%*, confirmation by TEM was performed.______________________________ ____________ If TEM was less than 1%, no further action was taken._____________________________ |lf TEM was greater than 1%, further action was taken. If PLM was greater than 1%, confirmation by TEM was unnecessary and further action was taken.

Air: If PCM was less than 0.003** f/cc, no further action was taken. ____________________________________ If PCM was greater than 0.003 f/cc, confirmation by TEM was performed._____________________________ If TEM was less than 0.01 f/cc, no further action was taken._________________ __________ ____________ If TEM was greater than 0.01 f/cc (did not occur), further action would have been needed. If PCM Is greater than 0.01*** f/cc, confirmation by TEM was performed.

■ A material is considered to be asbestos-containing material if it contains more than 1% asbestos using the PLM method. When asbestos was detected, only Chrysotile asbestos was found. *• 0.003 is the upper range (0.001 - 0.003) of background indoor air fiber concentrations determined in non-impacted areas. ••• Asbestos clearance criteria. Rules of the City of New York, Title 15. Chapter 1.

Results for Asbestos in Air and Settled Dust

Building Asbestos in Asbestos in Asbestos in Location Fibers in Air Number Dust Dust Air

Residential Buildings in Lower Manhattan

Building 1 PLM 1%] TEM [%] PCM [f/CCl TEM [f/ccj 1 Outside ND Not Sampled 0.001 NA 1 Common Not Sampled Not Sampled <.001 NA 1 Res t ND Not Sampled 0.006 <.001 1 Res 2 NDNot Sampled <.001 NA ^uildingJ Not^rcf£result3 atJ1esJI exceeded 0^02 f/cc Asb6StosJibers were noLdetected in this samplej3yJTMa^^ There was not enough material left to analyze the outdoor and residential dust samples by TEM.

Building 2 PLM [%) TEM [%] PCM [f/cc] TEM [f/cc] 2 Outside <1 1.2 0.003 NA 2 Common ND Not Sampled 0.005 <001 2 Rest ND Not Sampled <.001 NA 2 Res 2 ND Not Sampled 0.002 NA 2 Window Sill <1 <1 NA NA 2 Outside X 1.3 NA Not Sampled NA Buildin£^jyotes^__DEP_inspecte£jind2oi£id_asbestos-containing_materiaHrrme£utdoor_tocation_whfchj«a3jhenprafessionallyabate^ _____ _________________ PCM results exceeded 0.003 f/cc in the common area. Asbestos fibers were not detected in this sample by TEM analysis. There was not enough material left to analyze the indoor dust samples by TEM.

Building 3 PLM (%J TEM [%] PCM [f/cc] TEM (f/ccl

CITY_21MC100_000938200 NYC-WTC_000320589

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320589Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →