NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Draft Letter: Battery Place asbestos results, 2002

Machine-extracted title · confidence 28%

Draft letter detailing airborne fiber concentrations at Battery Place residences from November 2001.

NYC-WTC_000320541–000320542
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Draft Letter, January 24,2002

Summary of Asbestos Sampling Results Page 2 of 2

Address: 70 Battery Place Date sampled: November 19, 2001

DUST TEST RESULTS

Fibrous materials in dust found by Polarized Light Microscopy (PLM) Analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst will count the fibers present to give an estimate of fiber content as a percent.

Area Sampled Outside Outside** Common Residence Residence 1 2

Sample Numbers SA-O-10 SA-O-X-10** VA-C-10 VA-Rl-10 VA-R2-10

Asbestos present in dust: None None None None None Detected Detected Detected Detected Detected

Asbestos in dust as determined by Transmission Electron Microscope (TEM) Analysis: TEM analysis was conducted on all dust samples that showed asbestos content by PLM as less than 1%. TEM analysis is very specific, can detect smaller fibers of asbestos and is sensitive to less interference. This analysis was done to confirm the PLM findings of no asbestos shown above.

Area Sampled Outside Outside** Common Residence 1 Residence 2 Sample Numbers SA-O-10 SA-O-X-10** VA-C-10 VA-Rl-10 VA-R2-10 Asbestos (Chrysotile) None < 1% 1.5 % None Detected None Detected Detected present in dust < 1 %***

** Denotes a co-located sample

*** Denotes re-analysis of original sample for quality control purposes

T;\wlc\WTC Residential Sampling Project\OCCUPANT-OWNER COMMUNICATION\Drfl-70BatleryPlBldglO-0129Q2.doc

CITY_21MC100_003035492

NYC-WTC_000320542

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320542Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301443

Dust sampling results for Nov 18, 2001 at 99 Battery Place with TEM/PLM analyses.

Similar indexed content

Compare copies and versions →