NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 145 pages

WTC Background Study, EPA report draft

Machine-extracted title · confidence 28%

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

NYC-WTC_000320385–000320529
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

•a

5755-95 that “The collection efficiency of this technique is unknown and will vary among substrates. Properties influencing collection efficiency include surface texture, adhesiveness, electrostatic properties and other factors.”

For the purpose of this Study, lead dust samples were collected using microvacuum techniques for the determination of lead on a loading basis (microgram of lead per area sampled). As stated in section 1.3 of the ASTM Standard E 1973-99, “Due to a number of physical factors inherent in the vacuum sampling method, analytical results for vacuum dust samples are not likely to reflect the total dust contained within the sampling area prior to sample collection. This practice generally will have a collection bias towards smaller, less dense particles.’’ a 4.1.3 Wipe Sample Collection Wipe samples of settled dust, fi-om nonporous hard surfaces were collected from each unit and analyzed for asbestos, lead, dioxins, PAHs, crystalline silica, calcite, gypsum and total dust7=The methods used for the collection and analysis of wipe samples are summarised,in Table 4-1.

Wipe sampling empibys the use of a cloth like material(e.g., gauze or baby wipes), wetted or pre-moistened with a solution and is conducted by wiping an area within a template of known size.

4.1.4 Bulk Dust Sample Collection 4'xv During the development of the sampling plan and QAPP, no standard method was found for the collection of dust and particulate matter trapped in window air­ conditioner filters. EPA’s contractor TRC developed a procedure to collect this material by brushing the dust and particulate matter from the filter using a disposable brush. The dust was collected into a foil lined-stainless steel bowl. If sufficient material was obtained, the sample was transferred to the appropriate sample container for shipment to the laboratory. The procedure is noted in Table 4-1 of this report.

In several cases there was not enough material on the window air-conditioner filter for all of the analyses to be conducted. An order prioritizing theianalyses was established in the event of insufficient material collected. The first container was sent for the analysis of asbestos and MMVF. If sufficient sample material was collected for the remaining parameters, the second container was sdht for analysis of lead, crystalline silica, calcite and gypsum in descending priority.

Dust and particulate matter of sufficient amount could not be collected from any of the apartment air-conditioning unit filters for the analysis of PAHs and dioxins. These parameters require a large quantity of material in order to conduct the analyses.

WORLD TRADE CENTER BACKGROUND STUDY 10

CITY_21MC100_004053166 NYC-WTC_000320400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →