WTC airborne/dust exposure report draft, 2002

Machine-extracted title · confidence 30%

Draft report on potential exposures to airborne and settled surface dust in residential areas.

NYC-WTC_000320259–000320327
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Draft: Do not Cite, Quote, or Release May 30, 2002 Last saved by CVLee

519 Details on the methods used in the residential sampling investigations are included in the 520 residential sampling plan that is on the New City Department of Health’s Internet page 521 (http://wvvw.nvc.gov/html/doh/pdf/alerts/indoorl.pdf). The discussion here focuses on 522 the modifications to the protocol and the data handling and analysis. 523 524 Samples Taken 525 Sample collection was conducted from November 4, 2001 to December 11, 2001 526 for the lower Manhattan area and from December 6-10, 2001 for the comparison 527 buildings. Thirty buildings in Lower Manhattan were sampled and 4 comparison 528 buildings were sampled from the area north of 59th Street. In the 30 Lower 529 Manhattan buildings, the following locations were sampled: 59 Residential units, 530 29 Common areas, and 29 Outdoor areas. 531 532 There were 127 air samples taken from 117 different areas of the lower Manhattan 533 buildings. Ten of the areas had co-located sampling equipment. In the 59 534 different residential units, there were 64 air samples taken. Thirty air samples 535 were taken from 29 different common areas. 536 537 The samples taken from the four comparison buildings included: 3-lhrec oLitside 538 air samples, (no outside settled dust samples were collected as (there was no 539 visible dust to collect), 3-three common areas with both indoor settled dust and 540 air, and oTive residential units with both indoor settled dust and air. 541 542 Table 3 shows the number of buildings and areas within the buildings that were 543 sampled for asbestos in Lower Manhattan and the background units above 59* 544 Street and identifies the number of air and dust samples take from each area and 545 that werc analyzed for asbestos. Tables 4 and 5 provide similar information for the 546 airborne and settle dust sampling. Tables RX and RB in the back show the 547 building niunbers for each of these categories. 548 549 Field and Laboratory changes from the original sampling protocol 550 Field changes: 551 The sampling protocol indicated that a total of 60 residential units would be tested 552 in lower Manhattan. A total of 59 residential units were sampled. 553 554 Indoor settled surface dust was collected using U.S. Environmental Protection 555 Agency Environmental Response T-eam Standard Operating Procedure (EPA 556 ERT SOP) for household dust, as stated in the sampling protocol. However, due 557 to cost and equipment availability restraints constraints. Omega Ultivac vacuums 558 with HEPA filters were used instead of Nilfisk™ vacuums. To avoid the 559 needhaying to decontaminate the vacuum hose between each sampling event, a 560 sample collection filter (Alsock, by Midwest Filtration) was inserted into the air 561 intake end of the vacuum hose. (How was the flow rate evaluated using this 562 vacuum and the sock method to confirm that this modification maintained the

CITY_21MC100_012171104

NYC-WTC_000320280

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320280Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →