liNancy Jeffery-'COCapproach^J Page 2 i|

To: Maddaloni.Mark @ epamail.epa.gov 03/12/02 01 ;45 PM cc: kcarlino® health.nyc.gov, [email protected] Subject: Re: Next conference call for the indoor Taskforce COC/Benchmarks Committee(Document link: Robert L. Chinery)

Hi Mark,

I wanted to discuss with you some thoughts and data related to the choice of materials that may be specific markers for WTC dust. I think the data is indicating that fiberglass may be the best and least equivocal material that is an indicator of the presence of WTC demolition related dust. The following findings appear to indicate this.

1. The ATSDR/NYC indoor study sampled for many building related materials and minerals the only consistent finding in most residences around WTC (even after cleaning) was fiberglass in dust. In 43 of 98 samples (indoor and out) contained fiberglass. The hits ranged from 2-72% in dust by volume. The background samples were limited but no fiberglass was found in these samples. 2. The NIEHS summary we discussed yesterday indicated that UMDNJ (probably Paul Lioy) found 40-50% fiberglass in dust in three dust samples taken 1 -week post collapse. 3. Our microscopist Dr. Jim Webber, who wrote the methods used to identify asbestos by TEM and PLM, has been analyzing air/bulk dust samples from WTC provided by DEC and states he commonly sees fiberglass in the PLM analysis. The fibers tend to be thicker and longer than the asbestos fibers. 4. Dr. Eric Chatfield, a consultant to the "Ground Zero" Elected Officials Task Force sampled dust about a week after the collapse. He analyzed it for metals, dioxins and asbestos. Jim Webber has spoken with Dr. Chatfield and he has stated that he was also seeing fiberglass in these samples. As an additional note, Chatfield stated in the report that the dioxins/furans and metals levels in the bulk and wipe samples were indistinguishable from background. These were indoor dust (bulk and wipe) samples from a "high exposure location" on South end Ave. and a "low-exposure location" on Warren Street.

It would seem that if we wanted a good indicator of WTC related dust fiberglass may be the answer, ft appears that the background may be between ND (approx. 2%) to 5% by volume according to Jim Webber and ATSDR. All 8 background ATSDR/NYC study samples were ND.

One potential problem is that there is no generally accepted and validated method for the analysis of fiberglass; The current method used is a variation of a method written by Jim Webber for asbestos and would be considered "semi-quantitative". This is because it requires an operators estimate of the volume of fiberglass compared to the volume of the rest if the material on the slide (a 2-dimensional view).

However, given this caveat, fiberglass appears to be a much better indicator of the presence of WTC material than many of the other material

CITY_21MC100_003050683

NYC-WTC_000320140

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320140Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000176130

Lab report excerpt about planning post-9/11 indoor air sampling conference call.

Similar indexed content

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

Compare copies and versions →