NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

AF-related public health article, 2000s

Machine-extracted title · confidence 28%

MMWR article on atrial fibrillation and health care implications (unrelated to WTC data specifics).

NYC-WTC_000354197–000354202
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

132 MMWR February 21,2003

Readiness Force* and the WTC Environmental Assessment The XRD analysis for crystalline minerals was semiquantitative Working Group ', .assessed the composition of outdoor and (i.e., estimated). Air samples for fibers were analyzed first by indoor settled surface and airborne dust in residential areas phase contrast microscopy (PCM) (5). If the concentration around the WTC and in comparison areas. This report sum­ of total fibers wa.s higher than the maximum concentration marizes the results of the investigation, which found 1) simi­ of fibers found in the comparison homes (0.003 fibers per lar levels of airborne total fibers in lower and in upper cubic centimeter of air [f/cc]), the sample was re-analyzed for Manhattan, 2) greater percentage levels of synthetic vitreous asbestos fibers by using transmission electron microscopy fibers (SVF) and mlner.il components of concrete and build­ (TEM) (5). In addition, scanning electron microscopy (SEM) ing wallboard in settled dust of residential areas in lower to look for SVF was used for PCM fiber counts >0.003 f/cc if Manhattan than in upper Manhattan, and 3) low levels of the settled surface dust sample from that area contained SVF. asbestos in some settled surface dust in lower Manhattan resi­ Settled surface dust samples also were taken at each sam­ dential area.s ( /). Based in part on the results of this investiga­ pling location and analyzed for crystalline minerals and fibers tion, the U.S. Environmental Protection Agency (EPA) is (Figure). Fiber analysis of settled dust samples tor asbestos cleaning and sampling residential areas a.s requested by lower and SVF was conducted by using polarized light microscopy Manhattan residents. In addition, to assess any short- or Ion:ig- (PLM) (7). If asbestos levels were below the detection limit term health effects of smoke, dust, and airborne substances (i.e., < 1%), samples were re-analyzed by using TEM (7)- The around the WTC site, DOHMH and ATSDR are develop­ dust samples also were analyzed tor crystalline mineral con­ ing a registry that will track the health of persons who were tent by using XRD. most highly' e.xposed to these materials. During November 4-December 11, 2001, air and settled Air Sampling Results .surface dust samples were collected in and around 30 residen­ For 111 (94.9%) of the 1 17 tiir samples, the concentrations tial buildings w'ithin three concentric circles surrounding the of fibers found in lower Manhattan residential areas were simi­ WTC site in lower Manhattan, including 59 residential units lar to the concentration of fibers found in comparison areas (2). In addition, five residential unlt.s in four buildings (<0.003 f/cc).The six lower Manhattan areas that had elevated located north of 59th .Street (approximately 5 miles northeast total fiber counts were re-examined by TEM and SEM to of the WTC site) were sampled (or purposes of comparison. determine the type.s of fibers; the results indicated that nei­ Attention was tocused on building material constituents 1) ther asbesto.s nor SVF (e.g., fiberglass) contributed to the that have irritant properties (e.g., .SVF, including fiberglass elevated rota) fiber counts. and gypsum) or might have negative long-term health effects Air sampling results for minerals detected quartz and other (e.g., crystalline silica and asbestos) and 2) that were reason­ building material constituents in lower Manhattan. No other ably presumed to be either in the initial WTC collapse dust form.s of crystalline silica were detected in any air samples cloud or in dust generated bv subsequent rescue and recovery' except for a one-time detection of cristobalite (I 3 micrograms activitie.s at the WTC site. All samples collected during the per cubic meter [//g/m-^]h. The estimated concentrations of investigation were analyzed lor the presence of asbestos, SVF, these minerals in air were low. In some locations, mineral com- crystalline mineral components of concrete (e.g., silica, cal­ cite, and portlandite), and crystalline mineral components of 5 Estimated.

building wallboard (e.g., gypsum, mica, and halite). At each sampling location, time-weighted air sampling was FIGURE. U.S. Public Health Service commissioned officer collecting samples from a previously cleaned interior conducted for three or four particulate matter (PM) fractions residential area — New York City, November 2001 (i.e., PM 100 microns, 10 microns, 4 microns, and 2.5 microns) (3-5). Each PM fraction was analyzed for crystal­ line minerals by using X-ray diffraction (XR.D) analysis (6).

'A cadre of PH.S Coinnussioned Coip.s othcers who can be mobilized during 3»sc disaster, strife, or other public health emergencies and in response to domestic or international rct[ut5is. A group formed on September 15. 2001. that comprises representatives of the U.S. Department of Health and Human Services, Environmental Protection Agenev (EPA), Department of Labor, and New York State and NYC government and private organizations to coordinate public health and occupational sampling and data review jinong the three federal agencies in support of state and city health departments. PhotoZU.S, Public Health Service

CITY_21MC100_002995428

NYC-WTC_000354198

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354198Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279335

Medical article discussing atrial fibrillation and public health implications (unrelated to site data).

Similar indexed content

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

Compare copies and versions →