NYC-WTC_000321610
Foreword describing residential dust and indoor air sampling protocol near the WTC, Feb 2002.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Ambient and settled dust sampling protocol for residential areas near WTC.
NYC-WTC_000320059–000320106OCR status: ok · source: pdftotext
z ■<
NYC Backgrountf PCM/PCMe'f/cc * No restriction on access to any area. AHERA standards (40 CFR • Remediation goal is to achieve background levels. (see footnotes 2 and 3) 763); ATSDR Toxicological • AHERA guidance for schools requires that when schools are remediatedfor o co § Profile for A.shestas: OSHA asbestos, the indoor air levels of asbestos should be similar to local outdoor air
c o o Ca5 NYC Backsround to 0.01 f/cc PCM/PCMe^ • No restriction on access to streets aiul public/ 29 CFR 1926.1101
AHERA standards (40 CFR levels. • Lowest attainable cancer risk
• No significant cancer risk for short-term occupancy for residential and school 1 I ro o commercial building; continue to monitor 763); ATSDR Toxicoiosical buildings. o • Evaluate to determine if long-term access is acceptable; Profile for Asbestos; IRIS; • AHERA guidance for schools requires that when schools are remediated for o evaluate trends- over months. OSHA 29 CFR 1926.1101 asbestos, the indoor air levels ofashe.stas should he similar to local outdoor air 0 O " Identify source levels i O c » Take action, as practical, to reduce levels to 3 Q background 3
70 stntctnres/rntir TEM • If < than 70 s/mnd, no restrictions on access to buildings AHERA .standards (40 CFR • AHERA standards apply only to schools, and by NYC ordinance to buildings. e If > 70 s/rnm', resample to canfirtn and analyze field 763) • Method sensitivity and counting rules shouldfollow Appendix A (Table I) in blanks; take action to identify source and reduce levels to < NYC Clearance standardfor AHERA 40 CFR 763: Method sensitivity based on # grid.s analyzed and air 70 .s/mm^ buildings sample volume and must he maintained at 0.005f/cc.
0.0i - 0.1 f/cc PCM/PCMe^ • Continue to monitor; consider the need for additional Lowest limit set at l/IO • Long-term exposure.^ may increase cancer risk in the general public. sampling sites. PEL/RELH'LV; AHERA • Unlike workers the general population, include.'i children and sensitive • If air levels are consistently between 0.01 to 0.1 f/cc, standards (40 CFR 763); persons, does not receive exposure monitoring and doe.s not participate in annual evaluate the needfor advisories, the need to limit ATSDR Toxicological Profile health screening access and the need for dust suppression.. for Asbestos; IRIS; OSHA 29 CFR 1926.1101;
> 0.1 f/cc PCM/PCMe^ * Evaluate the need to restrict general public access. Unacceptable cancer risk General public should not be exposed to leveE suspected of adverse health effects • Continue to monitor; consider the needfor additional following long-term exposure; upon long-term exposure. sampling sites.. AHERA standards (40 CFR 763); ATSDR Toxicological Profile for Asbestos; IRIS; OSHA 29 CFR 1926.1101
I. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Documents and infortnation that were coiwidered in setting the action level. 3. Background levels for NYC are being detennined. 4. PCM equivalents (PCMe) is determined using TEM analysis and counting fibers > 0.3 /jm in diameter and > 5 /mt in length. PCMe should be determined using consistent methods to provide comparable concentrations. If PCM is exceeded, may need to detennine PCMe using TEM. Use professional judgement to determine ifPCMe is needed by e\’aluating the frequency and magnitude of exceedance, size of geographic area involved, and trends in data.
O
K I
O o o‘ I ' o o
[\j
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000321610
Foreword describing residential dust and indoor air sampling protocol near the WTC, Feb 2002.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452382
Continuation of protocol for indoor/dust sampling in Lower Manhattan WTC area.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452335
Protocol description for indoor and dust sampling around World Trade Center area.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445166
Sampling protocol and foreword for post-9/11 residential indoor and dust assessments in Lower Manhattan.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434617
Chain-of-custody for ambient and indoor dust sampling protocol used in WTC-related residential evaluations, Feb 2002.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452428
Continuation of protocol documentation for WTC dust/air evaluations.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443696
Dust and indoor sampling protocol for Lower Manhattan residential buildings after WTC disaster.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450478
Foreword describing residential building sampling plan and interagency collaboration after 9/11.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445447
Chain-of-custody covering indoor and dust sampling plan after WTC disaster (Feb 2002 Foreword).
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449245
Ambient and residential building sampling protocol for WTC-related investigations.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452289
Ambient and indoor dust sampling protocol for Lower Manhattan residential buildings.
19 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000321708
Final ATSDR/CDC/EPA/OSHA recommendations and AHERA guidance for WTC-related asbestos exposure.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319848
Summary of background asbestos levels and AHERA guidance for school remediation.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250481
Interpreting sampling results and when health review is warranted.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250891
Final draft chain-of-custody for ambient dust evaluations near the World Trade Center, Nov 2001.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289635
Final/draft note on follow-up sampling results from ATSDR residential studies.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000321610
Foreword describing residential dust and indoor air sampling protocol near the WTC, Feb 2002.
Similar indexed content
NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
Similar indexed content
NYC-WTC_000452382
Continuation of protocol for indoor/dust sampling in Lower Manhattan WTC area.
Similar indexed content
NYC-WTC_000452335
Protocol description for indoor and dust sampling around World Trade Center area.
Similar indexed content
NYC-WTC_000445166
Sampling protocol and foreword for post-9/11 residential indoor and dust assessments in Lower Manhattan.
Similar indexed content