NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

Lab report: Appendix B screening guidelines, Nov 8 2001

Machine-extracted title · confidence 49%

Interpreting sampling results and when health review is warranted.

NYC-WTC_000250481–000250490
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DRAFT (Version 11), Novembers, 2001**** FINAL (October 11, 2001) ATSDR, CDC, EPA. OSHA Environmental Assessment Workgroup Asbestos Action levels for World Trade Center Response

Action Level & Analysis Method General Public/Recommendations' Supporting Information’ Comments

NYC Background’ PCNbPCMe’ f/cc • No restriction on access to any area. AHERA standards (40 CFR • Remediation goal is to achieve background levels. , (see footnotes 2 and 3) 763); ATSDR Toxicological • AHERA guidance for schools requires that when schools are remediated for Profile for Asbestos; OSHA asbestos, the indoor air levels of asbestos should be similar to local outdoor air 29 CFR 1926.1101 levels. • Lowest attainable cancer risk

NYC Background to 0.01 &cc PCM/PCMe’ • No restriction on access to streets and public/ AHERA standards (40 CFR • No significant cancer risk for short-tenn occupancy for residential and school commercial building; continue to monitor 763); ATSDR Toxicological buildings. • Evaluate to determine if long-term access is acceptable; Profile for Asbestos; IRIS; • AHERA guidance for schools requires that when schools are remediated for evaluate trends over months. OSHA 29 CFR 1926.1101 asbestos, the indoor air levels of asbestos should be similar to local outdoor air ■ Identify source levels ■ Take action, as practical, to reduce levels to background

70 structures/mm’ TEM • If < than 70 s/mm’, no restrictions on access to buildings AHERA standards (40 CFR • AHERA standards apply only to schools, and by NYC ordinance to buildings. • If > 70 s/mm’, resample to confirm and analyze field 763) • Method sensitivity and counting rules should follow Appendix A (Table 1) in blanks; take action to identify source and reduce levels to < 70 NYC Clearance standard for AHERA 40 CFR 763; Method sensitivity based on # grids analyzed and air s/mm’ buildings sample volume and must be maintained at 0.005 ficc.

0.01-0.1 fZcc PCM/PCMe’ • Continue to monitor; consider Ute need for additional Lowest limit set at 1/10 • Long-term exposures may increase cancer risk in the general public. sampling sites. PEiyREl/TLV; AHERA • Unlike workers the general population, includes children and sensitive • If air levels are consistently between 0.01 to 0.1 f/cc. standards (40 CFR 763); persons, does not receive exposure monitoring and does not participate in annual evaluate the need for advisories, the need to limit ATSDR Toxicological Profile health screening access and the need for dust suppression.. for Asbestos; IRIS; OSHA 29 CFR 1926.1101;

>0.1 f/cc PCM/PCMe’ • Evaluate the need to restrict general public access. Unacceptable cancer risk General public should not be exposed to levels suspected of adverse health • Continue to monitor; consider the need for additional following long-term exposure; effects upon long-term exposure. sampling sites.. AHERA standards (40 CFR 763); ATSDR Toxicological Profile for Asbestos; IRIS; OSHA 29 CFR 1926.1101

I. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Documents and information that were considered in setting the action level. 3. Background levels for NYC are being determined. 4. PCM equivalents (PCMe) is determined using TEM analysis and counting fibers >0.3 /rm in diameter and > 5 /rm in length. PCMe should be determined using consistent methods to provide comparable concentrations. If PCM is exceeded, may need to determine PCMe using TEM. Use professional judgement to determine if PCMe is needed by evaluating the frequency and magnitude of exceedance, size of geographic area involved, and trends in data.

n

r LO 1—1 S Action Levels for Respirable Silica n General Public/Residents r o Draft 10-18-01, 3:30 p.m. CO

Page 35 of 41

NYC-WTC_000250484

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250484Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →