ATSDR/NYC background to 0.01 PCM/PCMe, AHERA guidance

Machine-extracted title · confidence 47%

Summary of background asbestos levels and AHERA guidance for school remediation.

NYC-WTC_000319848
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FINAL (September 27,2001) ATSDR, CDC, EPA, OSHA Environmental Assessment Workgroup Asbestos Action Levels for World Trade Center Response

Action Level (f/cc) & Analysis Method General Public/Recommendations' Basis Comments

NYC Background’ PCM/PCMe’ • No restriction on access to any area. Lowest attainable cancer • Remediation goal is to achieve background levels. (see footnotes 2 and 3) risk ® Considered AHERA guidance for schools which requires that indoor air levels for schools, remediated for asbestos, should be similar to local outdoor air levels for schools.

NYC Background to 0.01 PCM/PCMe’ • No restriction on access to streets and public/ AHERA standards (40 No significant cancer risk for short-term occupancy for residential and commercial building; continue to monitor CFR 763) school buildings. o Evaluate to determine if long-term access is acceptable; evaluate trends over months. ■ Identify source ■ Take action, as practical, to reduce levels to background

0.01 - 0.1 PCMrt’CMe’ • Continue to monitor; consider the need for additional Lowest limit set at 1/10 • Long-term exposures may increase cancer risk in the general public. sampling sites. PEI7RE17TLV o Unlike workers the general population, includes children and sensitive • If air levels are consistently between 0.01 to 0.1 f/cc, persons, does not receive exposure monitoring and does not participate in evaluate the need for advisories, the need to limit annual health screening access and the need for dust suppression..

>0.1 PCM/PCMe’ • Evaluate the need to restrict general public access. Unacceptable cancer risk General public should not be exposed to levels suspected of adverse • Continue to monitor; consider the need for additional following long-term health effects upon long-term exposure. sampling sites.. exposure — —— — Action levels (f/cc) for workers involved in Disaster Response and Recovery Workers Basis Comments emergency response and recovery activities (follow applicable OSHA standards)

0.1 PCM only • Respiratory protection required for workers, based on PEL Value, 0.1 f/cc based on an eight hour time weighted average, is the an 8 hour time weighted average (TWA) of exposure of Occupational Safety and Health Administration’s (OSHA) Permissible 0.1 PCM. Longer shift work, i.e., lower levels of Exposure exposure Limit for asbestos, as specified in the OSHA Construction Industry (i.e., the proportional maximum exposure for a 12-hour Regulation for Asbestos, 29 CFR 1926.1101. shift is 0.07 f/cc PCM).

1.0 PCM only • The maximum allowable level for workers average STEL Value, 1.0 f/cc measured over a 30-minute period, is the Occupational over 30 minute period (OSHA short term exposure Safety and Health Administration’s (OSHA) Short-Term Exposure Limit Q level). for asbestos, as specified in the OSHA Construction Industry Regulation H • PPE required above 1.0 f/cc PCM. for Asbestos, 29 CFR 1926.1101. K 1 I—i 1. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Background levels for NYC being determined. 3. PCM equivalents (PCMe) is s o determined using TEM analysis and counting fibers > 0.3 /tm in diameter and > 5 gm in length. PCMe should be determined using consistent methods to provide comparable concentrations. If PCM o is exceeded, may need to determine PCMe using TEM. Use professional judgement to determine if PCMe is needed by evaluating the frequency and magnitude of exceedance, size of geographic area 1° involved, and trends in data. o o

NYC-WTC_000319848

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319848Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →