October 16, 2001
Considerations for using the asbestos “1% rule” for cleaning up bulk contamination associated with the World Trade Center terrorists attacks.
Purpose; The purpose of this fact sheet is to discuss the basis of the 1% rule for asbestos containing material (ACM) and suggest how it may be applied to cleaning up asbestos contaminated debris from the World Trade Center collapse. The intent is to provide guidance for the use of bulk sampling results that will be protective of public health.
Background; The definition of asbestos containing material was first found in the Asbestos Hazard Emergency Response legislation of the United States Code. The term "asbestos-containing material" means any material which contains more than 1 percent asbestos by weight (see, United States Code, Title 15 - Commerce and Trade, Chapters 53 - Toxic Substances Control, Subchapter n - Asbestos Hazard Emergency Response, Sec. 2642. Definitions; which can be found at http ://www4. law .cornel 1 .edu/uscode/15/2642 .html).
This definition was codified in the Code of Federal Regulations (40 CFR Chi, 7-1-00 edition, part 763) where a counting technique using polarized light microscopy (PLM) are used to determine percent asbestos. % asbestos = (a/n) X 100% where a = number of asbestos counts, n = number of nonempty points counted (400), If a = 0, report “No asbestos detected”. If 0< a ^3 report “<1% asbestos”.
Historical derivation of the definition of “asbestos containing material”: Two different accounts of the discussions leading to the definition of asbestos-containing material being material containing greater than 1% asbestos exist.
1) The first account suggest that in the late 1970's when EPA was looking at the different methods to examine bulk material for asbestos they considered several different methods including polarized light microscopy (PLM), electron microscopy, x-ray diffraction (XRD), and others. EPA eventually settled upon XRD. XRD had a detection limit of approximately 1% asbestos in bulk material. Eventually the limitations of XRD became an obstacle to reliable asbestos determinations and EPA looked toward PLM to replace XRD as the analytical tool of choice. However, even though PLM can detect well below 1% asbestos, the 1% number had become well accepted and had been written into legislation, and so therefore 1% remained the legally enforceable number.
2) The second account suggests that the 1% rule has a political basis and resulted as a compromise between regulators and the regulated industry. An account of the politics
CITY_21MC100_006740711
NYC-WTC_000319796
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000320139
Final summary comparing PCM and TEM results and remediation goals to background levels.
6 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289740
Summary of recommendations and AHERA/OSHA guidance for asbestos remediation and background levels.
6 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319804
Final notes comparing asbestos standards and remediation guidance for World Trade Center response and school guidance.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250298
Final NYC background asbestos levels and remediation goals per AHERA/OSHA guidelines.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289635
Final/draft note on follow-up sampling results from ATSDR residential studies.
5 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307176
Final remarks from agencies regarding asbestos remediation goals and access.
6 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408400
Recommendations and background information for asbestos, MCA, and remediation goals at WTC site.
7 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139416
Multi-agency discussion of benchmark reference levels for probable indoor contaminants of concern, including asbestos in air.
8 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389927
Final/ draft notes outlining AHERA guidance and background asbestos standards for WTC sites.
6 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307385
Draft NYC WTC asbestos data recommendations and AHERA/OSHA context.
7 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163606
Strawman benchmarks for probable indoor contaminants of concern related to WTC assessment.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332162
ATSDR/CDC/EPA/OSHA collaboration on background asbestos sampling and remediation goals.
7 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000338190
Draft sampling protocol for ambient asbestos and dust exposure near World Trade Center residential areas.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241933
Draft ambient sampling protocol for WTC-related fiber and dust exposure assessments.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196150
Guidance document discussing the application of the 1 percent asbestos threshold rule for debris cleanup at Ground Zero.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250547
Ambient and residential evaluations near WTC, draft protocol version 9.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178091
Sampling protocol developed to assess residential exposure to airborne and settled dust near the World Trade Center.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000320139
Final summary comparing PCM and TEM results and remediation goals to background levels.
Similar indexed content
NYC-WTC_000307176
Final remarks from agencies regarding asbestos remediation goals and access.
Similar indexed content
NYC-WTC_000289740
Summary of recommendations and AHERA/OSHA guidance for asbestos remediation and background levels.
Similar indexed content
NYC-WTC_000319804
Final notes comparing asbestos standards and remediation guidance for World Trade Center response and school guidance.
Similar indexed content
NYC-WTC_000250298
Final NYC background asbestos levels and remediation goals per AHERA/OSHA guidelines.
Similar indexed content