NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 64 pages

EPA background report, WTC air contaminants, 1987

Machine-extracted title · confidence 29%

Background report on asbestos and related contaminants for WTC environment, 1987.

NYC-WTC_000318755–000318818
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 83 / Thursday, April 30, 1987 / Proposed Rules 15859

The readings should be repeated at be measured for the type of specimen EDS elemental analyses from different locations on the replica, and grids in use. This can be accomplished submicroscopic fibers, the present Level 1 the average of about six readings should on the TEM at a properly calibrated low II and Level III protocols specify the use be taken as the representative or true magnification or on an optical of only qualitative EDXA spectra, which magnification for that setting of the EM, microscope at a magnification of are often very valuable for screening as in the following example: approximately 400 by using an eyepiece purposes in the identification procedure. fitted with a scale that has been For example, in distinguishing between 1 Line spacings mm on Magnifica­ calibrated against a stage micrometer. tremolite and actinolite type of screen tion 19. Crystallography and amphibole, actinolite usually contains X Y M Morphological Properties; Fe, but tremolite does not. Both crystallographic and 21. Selected Area Electron Diffraction

i 83 18871

f 80 60 80 80 18560 16514 19636 • 19200 morphological characteristics of (SAED). The method of obtaining an asbestos minerals can help considerably SAED pattern of a randomly oriented in asbestos identification and analysis. specimen is usually described in the EM 1 ■ 80 19200 Chrysotile displays a unique narrow instruction manual. The general Average 19000 tubular morphology. The amphibole directions for using the instrument to asbestos minerals have very similar obtain and photograph SAED patterns On most EM’S with large (18-cm morphologies—they are elongated along are; diameter) fluorescent screens, the the z-axis (the chain direction) and a. Select the image magnification for magnification is substantially constant generally lie with (100) planes the selected area. { only with the central 8- to 10-cm- approximately perpendicular to the b. Bring the desired field of view to electron beam. All varieties of the center of the screen. diameter region. Therefore, calibration measurements should be made within amphiboles exhibit these Wadsley faults c. Insert the appropriate field-limiting this small region and not over the entire parallel to the length of the fiber. aperture (according to the desired field screen. Chrysotile possesses a cylindrical of view) into the beam bath. e. Calibration of the EDXA System. lattice which produces a unique SAED d. Obtain the sharpest field-limiting Initially, the EDXA system must be pattern. All the amphiboles, except aperture shadow. calibrated by using two reference anthophyllite, which is orthorhombic, e. Confirm that the desired field of elements to calibrate the energy scale of have a monoclinic crystal structure. The view is in the field-limiting aperture. ' the instrument. When thia has been amphiboles are double-chain silicates in f. Focus the specimen image; a completed in accordance with the - which the fiber axis, z, has a repeat of photograph of the selected area image manufacturer's instructions, calibration ■ 0.53 nm (inter-row spacing ‘R’ in real can be taken. in terms of the different types of . space]. Since the other lattice g. Obtain the SAED pattern. asbestos can proceed. The EDXA parameters are also very similar, remembering to retract the objective detectors vary in both solid angle of detailed zone-axis SAED analysis in lens aperture from the beam path. The detection and in window thickness. more.than one orientation is needed for. SAED pattern will be observed on the Therefore, at a particular accelerating ■ positive identification. The nonasbestos fluorescent screen. voltage in use on the TEM, the count forms of amphiboles have properties h. Select the desired camera length rate obtained from specific dimensions very similar to their asbestos (the shorter the length, the better for offiber will vary both in absolute X-ray counterparts, thus they must be SAED patterns of asbestos taken at high count rate and in the relative X-ray peak distinguished from asbestos on the basis' magnification). •heights for different elements. Only a of morphology alone. i. Focus the SAED pattern sharply. few minerals are relevant for asbestos Note.—This section and sections 19-26 The beam stopper is used to intercept abatement work, and in this procedure have been drawn from Reference 10. the bright center spot. the calibration is specified in terms of a- 20. Chemical Properties—Elemental J. For photography, the illumination is "fingerprint” technique. The EDXA Analysis by EDS: - expanded (condenser reduced) after i ■ spectra must be recorded from Amphiboles are nonstochiometric focusing the pattern, so that the pattern individual fibers of the relevant minerals and often contain becomes barely visible (indistinct). A minerals, and identifications are made. substitutional cations in varying manual time exposure of approximately on the basis of semiquantitative amounts. Therefore, precise . 20 to 30 seconds (maybe more comparisons with these reference determination of their chemistry is depending on such factors as specimen spectra. difficult and positive identification and film) is required. The beam stopper f. Calibration of Grid Openings. based on chemistry alone is not reliable. can be left in place or removed from the Measure 20 grid openings on each of 30 This may be particularly pertinent when beam path 1 to 2 seconds before closing random 200-mesh copper grids by dealing witli asbestos minerals present - the shutter. A double exposure of the ' .placing a grid on a glass slide and specimen image and the SAED pattern as minor constituents in mineral examining it under the PCM. Use the can be taken if particle-to-parficle samples. Walton-Beckett graticule to measure the Elemental ratios, which are sometimes spacing is adequate. grid opening diameters. Calculate an used to distinguish between asbestos 22. Use of Tilting to Acquire Exact average field diameter from the data types, often vary over wide ranges even Zone-Axis SAED Patterns; and use this number to calculate the field area for an average grid opening. in standard samples. The presence of Determination of the Tilt Axis. In the gold coating, which would tend to side-entry type electron microscopes, Grids to be randomly selected from batches up to 1,000. preferentially absorb X-rays from lighter the instrument tilt axis is always fixed. elements more than heavier elements, However, (he position of the tilt axis on Note.—A grid opening is considered as one may make the situation even worse. In the viewing screen shifts with field. view of these ambiguities, and due to magnification. Also, there is always an g. Measurement of Grid Opening inherent practical difficulties in angular rotation between the image and ■ Area. The mean grid opening area must obtaining representative quantitative the SAED pattern. It is highly desirable

NYC-WTC_000318795

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318795Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →