NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 64 pages

EPA background report, WTC air contaminants, 1987

Machine-extracted title · confidence 29%

Background report on asbestos and related contaminants for WTC environment, 1987.

NYC-WTC_000318755–000318818
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 83 / Thursday, April 30. 1987 / Proposed Rules 15853

4. Filter collapsing procedure. A 75 from the surface of a microscope slide pieces of lens tissue may be placed in mm X 25 mm microscope slide is washed held in the rotating and tilling device. the same Jaffe Washer. The lid is then in detergent, rinsed several times in 7. Carbon coating of collapsed and placed on the Jaffe Washer, and the distilled or filtered, deionized water, and etched filter. The glass slide holding the system is allowed to stand for several then allowed to dry. Twenty to 30 collapsed filter portion is placed on the hours, preferably overnight. microliters of the collapsing solution is rotation-tilting device, and the I. TEM specimen preparation from placed in the middle of. the slide by evaporator chamber is evacuated to a MEC filters (Method b)— 1. This using a disposable tip micropipet, and vaccum better than 0.013 Pa. The method of preparing TEM specimens the end of the pipet is used to spread the evaporation must be performed in very from MEC filters is similar to' that liquid out over the area to be occupied short bursts, separated by some seconds specified in NIOSH Method 7402 (Ref. by the quarter filter. The quarter filter. to allow,the electrodes to cool. If 9J. . . active surface upwards, is then laid on evaporation is too rapid, the surface of 2. Upon receipt at the analytical top of the solution and the edge of the the collapsed filter may be damaged laboratory, and before they are taken filter is lowered at an angle of about 20 from heating. An experienced analyst into the clean facility or laminar flow . degrees so that air bubbles are can judge the thickness of carbon film to hood, the sample cassettes must be > excluded. Solution not absorbed by the applied, and some tests should be be .. cleaned of any contamination adhering filter is then removed by allowing a made first on unused filters. If the film is ■ to the outside surfaces. After the analyst I tissue to contact the liquid at the edge of too thin, large particles will be lost from has checked to ensure that the cassette the filter. The slide is then placed either the TEM specimen, and there will be is tighdy sealed and the plugs are in in an oven at 65 to 70 degress C or on a few complete and undamaged grid both ends, it should .be thoroughly slide warmer at the same temperature, openings on the specimen. If the coating cleaned by rinsing with water and wet- for about 10 minutes. If the slide is too thick, the carbon film may not wiping and then dried with clean paper becomes too warm, bubbles will adhere to the support mesh. Too thick a towel. develop. The filter collapses slowly to carbon film will also lead to a TEM 3. Remove a section from any about 15 percent of its original image that is lacking in contrast, and the quadrant of the sample and blank filters. thickness. The procedure leaves a thin, ability to obtain SAED patterns will be 4. pia^e the section on a clean transparent plastic film, with particulate compromised. The carbon film should. be microscope slide. Affix the filter section and fibers embedded in the upper tfen as Possible and stil^tain most to the slide with a gummed page surface of the grid openings of the TEM reinforcement or other suitable means. 5. The Plasma etching of theon collapsed nf tho r ffo vt/ hor Label the slide with a waterproof filter. collapsed filter th^T-. . marking pen. The precise design of the Jaffe Washer 5. Place the slide in a petri dish which microscope slide is placed in a plasma is not considered important, so any one asher for a period of approximately 6 contains several paper filters soaked of the published designs may be used. with 2 to 3 ml acetone. Cover the dish. minutes. Because plasma ashers vary . The washer consisting of a simple greatly in their performance, both from Wait 2 to 4 minutes for the sample filter stainless steel bridge is recommended. to fuse and clear. unit to unit and between different Several pieces of lens tissue positions in the asher chamber, it is approximately 1.0 cm x 1.5 cm are Note.—The "hot block" clearing technique difficult to specify the conditions that of Method .7400 may be used instead of steps placed on the stainless steel bridge, and 4 and 5. should be used. This is one area of the the washer is filled with dimethyl method that requires.further evaluation. formamide to a level where the 6. Plasma Etching of the Collapsed , Insufficient etching will result in a • meniscus contacts the underside of the Filter. failure to expose embedded filters, and mesh, which results in saturation of the . a. The microscope slide to which the too much etching may result in loss of lens tissue. Like chloroform, dimethyl collapsed filter pieces are attached is particulate from the surface. As an formamide is a toxic solvent, and placed in a plasma ashers for a period of interim measure, it is recommended that appropriate precautions should be taken about 6 minutes. Because plasma ashers the time for ashing of a known weight of in its use. . vary gready in their performance, both a collapsed filter be established and that 9. Placing of specimens into the Jaffe from unit to unit and between different the etching rate be calculated in terms of Washer. The T^ ^ids are first placed positions in the asher chamber, it is micrometers per second. The actual on a piece of lens tissue so that difficult to specify the conditions that etching time used for a particular asher individual grids can be picked up with should be used. This is one area of the and operating conditions will then be set tweezers. method that requires further evaluation. such that a l-micrometer layer of Using a curved scalpel blade, the . Insufficient etching will result in a collapsed surface vvill be removed. analyst excises three 2 to 3 mm square failure to expose embedded fibers, and i. I 6. Preparation of the carbon pieces of the collapsed, etched, and too much etching may result in loss of I evaporator. Carbon coating must be carbon-coated filter from the quarter particulate from the surface. As an 1 performed with a high-vacuum coating filter. The three squares are selected interim measure, it is recommended that unit. Units that are based on' close to the apex of the sector, and at the time for ashing of a known weight of evaporation of carbon filaments in a two other points midway between the a collapsed filter be established, and vacuum generated only by an oil rotary apex and die outer edge. Each piece of that the etching rate be calculated in. pump have not been evaluated for this filter, carbon side up, is placed on a terms of micrometers per second. The application, and must not be used. The TEM specimen grid with the shiny side actual etching time used for the carbon rods should be sharpened with of the TEM grid facing upward, and the particular asher and operating the carbon rod sharpener to necks of whole assembly is placed boldy onto the conditions will then be set such dial a 1- about 3.6 mm long and 1.6 mm in saturated lens tissue in the Jaffe > micrometer layer of collapsed filter will diameter. The rods are installed in the Washer. The three’excised squares of be removed (Ref. 7 and 9J. evaporator in such a manner that the filter are placed on the same piece of b. Place the slide containing the points are approximately 10 to 12 cm lens tissue. Any number of separate . collapsed filters into a low-temperature

NYC-WTC_000318789

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318789Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →