NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 77 pages

Background study draft for WTC asbestos, 2003

Machine-extracted title · confidence 37%

Background study draft on asbestos in schools related to WTC, March 2003.

NYC-WTC_000318678–000318754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Federal Register / Vol. 52, No. 210 / Friday. October 30, 1987 / Rules and Regulations 41881

point placed in contact with the filter. meniscus contacts the underside of the ihatspi ifie-l in NIOSH Method 7402. The process can be repeated to cut a mesh, which results ip saturation of the See Refeieni ;8 7, 8. and 9 of Unit Ill.L. strip approximately 3 mm wide across lens tissue. See References 8 and 10 of b. Upon r .ceipt at the analytical the diameter of the filler. The strip of Unit Ill.L. laboratory, the sample cassettes must be polycarbonate filler is separated from g. Placing of specimens into the Jaffe cleaned of any contamination adhering the corresponding strip of backing filter washer. The TEM grids are first placed to the outside smfaces before entering and carefully placed so that it bridges on a piece of lens tissue so that the clean sample preparation area. the gap between the adhesive tape strips individual grids can be picked up with c. Remove a section from any on the microscope slide. The filter strip tweezers. Using a curved scalpel blade, quadrant of the sample and blank filters. can be held with fine-point tweezers and the analyst excises three 3 mm square d. Place the section on a clean supported underneath by the scalpel pieces of the carbon-coated microscope slide. Affix the filter section blade during placement on the polycarbonate filler from the filler strip. to the slide with a gummed paged microscope slide. The analyst can place The three squares are selected from the reinforcement or other suitable means. several such strips on the same center of the strip and from two points Label the slide with a water and microscope slide, taking care to rinse between the outer periphery of the solvent-proof marking pen. and wet-wipe the scalpel blade and active surface and the center. The piece e. Place the slide in a petri dish which tweezers before handling a new sample. of filter is placed on a TEM specimen contains several paper filters soaked The filter strips should be ideritified by grid with the shiny side of the TEM grid with 2 to 3 mL acetone. Cover the dish. etching the glass slide or marking the facing upwards, and the whole assembly Wait 2 to 4 minutes for the sample filter slide using a marker insoluble in water is placed boldly onto the saturated lens to fuse and clear. and solvents. After the filter strip has tissue in the Jaffe washer. If carbon- f. Plasma etching of the collapsed been cut from each filter, the residual coated grids are used, the filter should filter is required. parts of the filter must be returned to the be placed carbon-coated side down. The i. The microscope slide to which the cassette and held in position by three excised squares of filters are collapsed filter pieces are attached is reassembly of the cassette. The cassette placed on the same piece of lens tissue. placed in a plasma asher. Because will then be archived for a period of 30 Any number of separate pieces of lens plasma ashers vary greatly in their days or returned to the client upon tissue may be placed in the same Jaffe performance, both from unit to unit and request. washer. The lid is then placed on the between different positions in the asher e. Carbon coating of filter strips. The Jaffe washer, and the system is allowed chamber, it is difficult to specify the glass slide holding the filter strips is to stand for several hours, preferably conditions that should be used. This is placed on the rotation-tilting device, and overnight. one area of the method that requires the evaporator chamber is evacuated. h. Condensation washing. It has been further evaluation. Insufficient etching The evaporation must be performed in found that many polycarbonate filters will result in a failure to expose very short bursts, separated by some will not dissolve completely in the Jaffe embedded fillers, and too much etching seconds to allow the electrodes to cool.. washer, even after being exposed to may result in loss of particulate from the If evaporation is too rapid, the strips of chloroform for as long as 3 days. This surface. As an interim measure, it is polycarbonate filter will begin to curl, problem becomes more serious if the recommended that the time for ashing of which will lead to cross-linking of the surface of the filter was overheated a known weight of a collapsed filter be surface material and make it relatively during the carbon evaporation. The established and that the etching rate be insoluble in chloroform. An experienced presence of undissolved filter medium calculated in terms of micrometers per analyst can judge the thickness of on the TEM preparation leads to partial second. The actual etching time used for carbon film to be applied, and some test or complete obscuration of areas of the a particular asher and operating should be made first on unused filters. If sample, and fibers that may be present conditions will then be set such that a 1- the fihn is too thin, large particles will in these areas of the specimen will be 2 ;im (10 percent) layer of collapsed be lost from the TEM specimen, and overlooked: this will lead to a low result. surface will be removed. there will be few complete and Undissolved filter medium also ii. Place the slide containing the undamaged grid openings on the compromises the ability to obtain EU collapsed filters into a low-temperature specimen. If the coating is too thick, the patterns. Before they are counted, TEM plasma asher, and etch the filter. filter will tend to curl when exposed to grids must be examined critically to g. Transfer the slide to a rotating stage chloroform vapor and the carbon film determine whether they are adequately inside the bell jar of a vacuum may not adhere to the support mesh. cleared of residual filter medium. It has evaporator. Evaporate a 1 mm x 5 mm Too thick a carbon film will also lead to been found that condensation washing section of graphite rod onto the cleared a TEM image that is lacking in contrast, of the grids after the initial Jaffe washer filter. Remove the slide to a clean, dry. and the ability to obtain ED patterns treatment, with chloroform as the covered petri dish. will be compromised. The carbon film solvent, clears all residual filter medium h. Prepare a second petri dish as a should be as thin as possible and remain in a period of approximately 1 hour. In Jaffe washer with the wicking substrate intact on most of the grid openings of practice, the piece of lens tissue prepared from filter or lens paper placed the TEM specimen intact. supporting the specimen grids is on top of a 6 mm thick disk of clean f. Preparation of the Jaffe washer. The transferred to the cold finger of the spongy polyurethane foam. Cut a V- precise design of the Jaffe washer is not condensation washer, and the washer is nolch on the edge of the foam and filter considered important, so any one of the operated for about 1 hour. If the paper. Use the V-notch as a reservoir for published designs may be used. A specimens are cleared satisfactorily by adding solvent. The wicking substrate washer consisting of a simple stainless the Jaffe washer alone, the condensation should be thin enough to fit into the petri steel bridge is recommended. Several washer step may be unnecessary. dish without touching the lid. pieces of lens tissue approximately 1.0 8. TEM specimen preparation from i. Place carbon-coated TEM grids face cm X 0.5 cm are placed on the stainless MCE filters. up on the filter or lens paper. Label the steel bridge, and the washer is filled a. This method of preparing TEM grids by marking with a pencil on the with chloroform to a level where the specimens from MCE filters is similar to filter paper or by putting registration

NYC-WTC_000318734

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318734Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →