41884 Federal Register / Vok 52. No. 210 / Friday, October 30,. 1987 / Rules and Regulations

b. Check that the microscope is (3) It is too dark because of iii. Scan the grid as follows. properly aligned and calibrated incomplete dissolution of the filter. (1) At the selected magnification, according to the manufacturer’b iv. If the grid is rejected, load the next make a series of parallel traverses specifications and instructions. sample grid. across the field. On reaching the end of c. Microscope settings: 80-120 kV. grid V. If the grid is acceptable, continue one traverse, move the image one assessment 25O-1OOOX, then 15,000- on to Step 6 if mapping is to be used: window and reverse the traverse. 20.000X screen magnification for otherwise proceed to Step 7. Note.—A slight overlap should be used so analysis. f. Grid Map (Optional). as not to miss any part of the grid opening d. Approximately one-half (0.5) of the i. Set the TEM to the low (field), predetermined sample area to be magnification mode. (2) Make parallel traverses until the analyzed shall be performed on one ii. Use flat edge or finder grids for entire grid opening (field) has been sample grid preparation and the mapping. scanned. remaining half on a second sample grid iii. Index the grid openings (fields) to h. Identify each structure for preparation. be counted by marking the acceptable appearance and size. e. Determine the suitability of the grid. fields for one-half (0.5) of the area i. Appearance and size: Any i. Individual grid openings with needed for analysis on each of the two continuous grouping of particles in greater than 5 percent openings (holes) grids to be analyzed. These may be which an asbestos fiber within aspect or covered with greater than 25 percent marked just before examining each grid ratio greater than or equal to 5:1 and a particulate matter or obviously having opening (field), if desired. length greater than or equal to 0.5 /im is nonuniform loading shall not be iv. Draw in any details which will detected shall be recorded on the count analyzed. . allow the grid to be properly oriented if sheet. These will be designated asbestos ii. Examine the grid at low it is reloaded into the microscope and a structures and will be classified as magnification (<1000X) to determine its particular field is to be reliably fibers, bundles, clusters, or matrices. suitability for detailed study at higher identified. Record as individual fibers any magnifications. g. Scan the grid; contiguous grouping having 0.1. or 2 iii. Reject the grid if: i. Select afield to start the definable intersections. Groupings (1) Less than 50 percent of the grid examination. having more than 2 intersections are to openings covered by the replica are ii. Choose the appropriate be described as cluster or matrix. See intact. magnification (15.000 to 20,000X screen the following Figure 5: (2) It is doubled or folded. magnification). BILLING CODE SSeO-SO-M

NYC-WTC_000318737

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318737Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →