il860 Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations

7. Reloading of used cassettes is not 14. The final plastic barrier around the! c. Two field blanks are to be taken by permitted. abatement area remains in place for the removing the cap for not more than 30 8. Orient the cassette downward at sampling period. seconds and replacing it at the time of approximately 45 degrees from the 15. After the area has passed a sampling before sampling is initiated at horizontal. thorough visual inspection, use the following places: 9. Maintain a log of all pertinent aggressive sampling conditions ta i. Near the entrance to each sampling information. dislodge any remaining dust. (See abatement area. 10. Calibrate sampling pumps and suggested protocol in Unit III.B.7.d.) ii. At one of the ambient sites. (DO their flow indicators over the range of 10. Select an appropriate (low rate NOT leave the field blanks open during their intended use with a recognized equal to or greater than 1 liter per the sampling period.) standard. Assemble the sampling minute (L/min) or less than 10 L/min for d. A sealed blank is to be carried with system with a representative filter (not 25 mm cassettes. Larger filters may be each sample set. This representative f

the filter which will be used in sampling) operated at proportionally higher flow cassette is not to be opened in the field. before and after the sampling operation. rates. 18. Perform a leak check of the 11. Record all calibration information. 17. A minimum of 13 samples are to be sampling system at each indoor and 12. Ensure that the mechanical collected for each testing site consisting outdoor sampling site by activating the vibrations from the pump will be of the following: pump with the closed sampling cassette I minimized to prevent transferral of a. A minimum of five samples per in line. Any flow indicates a leak which I vibration to the cassette. abatement area. must be eliminated before initiating the 13. Ensure that a continuous smooth b. A minimum of five samples per sampling operation. flow of negative, pressure is delivered by ambient area positioned at locations 19. The following Table I specifies the pump by damping out any pump representative of the air entering the volume ranges to be used: action fluctuations if necessary. abatement site. BILUNQ CODE 8540-50-M

)

NYC-WTC_000318713

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318713Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →