Results of minerals and fibers in air, 53 Park Place,

Machine-extracted title · confidence 27%

enclosure detailing results of air and settled dust sampling near 53 Park Place in 2001.

NYC-WTC_000318634–000318637
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Explanation of Tables 2a and 2b: Fibers found in Air and Settled Dust at 53Park Place and the Comparison Areas: Please refer to the Executive Summary for details.

Air Sample Collection and Analyses The PCM method detects all fiber types in air. PCM results in one indoor location of your building were higher than those found in the comparison area samples. Therefore, this sample was re-analyzed using TEM (asbestos analysis) and SEM (fibrous glass analysis). The results of TEM showed asbestos less than 0.001 f/cc; the results of SEM showed fibrous glass at 0.00016 fZcc. These levels are similar to those found in comparison area samples and show that asbestos and fibrous glass contribute very small amounts to the overall fibers detected.

Table 2a Fibers in Air for 53 Park Place and the upper Manhattan Comparison Area (fibers per cubic centimeter of air) 53 Park Place Comparison Area* Fibers in Air Common Outdoor Residence Residence Common Outdoor Residences Area #1 #2 Area Total Fibers <0.001 0.001 0.006 <0.001 0.002 0.001 0.003 (PCM) Asbestos NA NA <0.001 NA NA NA NA (TEM) Fibrous glass NA NA 0.00016 NA 0.00004 0.00004 0.00009 (SEM) *Results are maximum values found in the comparison area PCM = phase contrast microscopy TEM = transmission electron microscopy SEM = scanning electron microscopy NA = not analyzed

Settled Dust Sample Collection and Analyses Indoor settled dust levels of 20% fibrous glass were found; none was detected in the comparison homes. Surface dust outside your building contained 22% fibrous glass. No visibly settled dust was available to collect in comparison building outdoor locations. The total amount of dust present was not determined. Only the percent fibrous glass in each sample could be determined. To lower potential exposures, fi-equent cleaning is recommended.

Table 2b Fibers in Settled Dust for 53 Park Place and the upper Manhattan Comparison Area (percent of fibers in sample) 53 Park Place Comparison Area* Fibers Common Outdoor Residence Residence Common Outdoor Residences In Dust Area #1 #2 Area Asbestos NS ND ND ND ND NS ND (PLM) Asbestos NS <1 NA NA ND NS ND (TEM) Fibrous NS 22 20 20 ND NS ND glass (PLM) *Results are maximum values found in the comparison area PLM = polarized light microscopy TEM = transmission electron microscopy

CITY_21MC100_008959029

NYC-WTC_000318636

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318636Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →