NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Final draft: asbestos background guidance

Machine-extracted title · confidence 25%

Final draft recommending background asbestos guidance and remediation considerations.

NYC-WTC_000318597
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

r FINAI4.Srpl««ilKT27.2001) ATSOK,r'Df'. O.S'IIA I'.iiviKiiiinciil.-iI Assessiimnl Wiiili’jiiiip AsbcsInsAclmiil^vcIsInrWnrldTrmlcCciHcrRcs^^

Action Level (f/cc) & Analysis Mclliod Gcnciiil I’liblic/Rcconinicndalions' Basis Comments

NYC Backc.iound’ PCM/PCMe' o Nil icstiictiun on acvvss to any aiva. Lowest allainabte cancer o Reinedialitin goal i.s to achieve background levels. (see footnotes 2 and .3) risk O Considered AllER A guidance for school.s which rci|uiic.s that indoor air levels for schools, remediated for asbestos, should be similar to local outdoor air levels for schools.

NYC Background to 0.01 I’CM/PCMc’ o No restriction on access Io sirecis and public/ AHERA standards (40 No significant cancer ri.sk for short-term occupancy for residential and commercial building; continue Io monitor CFR 76.3) school buildings. O Evaluate to determine if long-term access is acceptable; cvalualc trends over nionibs. o Identify source D Take action, as practical, to reduce levels to background

0.01 - 0.1 PCM/PCMe' ® Continue to monitor; consider the need for additional Lowest limit set at l/IO 0 Long-term exposures may increase cancer risk in the general public. sampling sites. PEiyREUTLV ® Unlike workers the general population, includes children and sensitive • If air levels arc consistently between 0.01 to 0.1 f/cc, persons, docs not receive exposure monitoring and docs not participate in evaluate the need for advisories, the need to limit annual health screening access and tlic need for dust suppression..

>0.1 PCM/PCMe^ ® Evaluate the need to restrict general public access. Unacceptable cancer risk General public should not be exposed to levels suspected of adverse ® Continue to monitor; consider the need for additional following long-term health effects upon long-term exposure. sampling sites.. exposure

Action levels (f/cc) for workers involved in Disaster Response and Recovery Workers Basis Comments emergency response and recovery activities (follow applicable OSHA standards)

0.1 PCM only o Respiratory protection required for workers, based on PEL Value, 0.1 f/cc based on an eight hour lime weighted average, is the an S hour lime weighted average (TWA) of exposure of Occupational .Safety and Health Administration’s (OSHA) Permissible 0.1 PCM. Longer shift work, i.e., lower levels of Exposure exposure Limit for asbestos, as specified in the OSHA Construction Industry (i.e., the proportional maximum exposure fora 12-hour Regulation for Asbestos, 29 CFR 1926.1101. shift is 0.07 f/cc PCM).

1.0 PCM only • The maximum allowable level for workers average ■STEL Value, 1.0 f/cc measured over a 30-minule period, is the Occupational over 30 minute period (OSHA short term exposure Safety and Health Administration's (OSHA) Short-Term Exposure Limit O level). for asbestos, as specified in the OSHA Construction Industry Regulation H ® PPE required above 1.0 f/cc PCM. for Asbestos, 29 CFR 1926. HOI. I ro

R I. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Background Icvcfs for NYC being determined. .3. PCM ctpiivalenl.s (PCMc) i.s determined using TEM analysis and counting fibers > 0.3 )im in diameter and > 5 gm in length. PCMc should be determined using consistent methods to provide comparable concentrations. If PCM o is exceeded, may need to determine PCMc using TEM. Use professional judgement todclcrniinc if PCMc is needed by evaluating the frequency and magnitude of exceedance, size of geographic area 1° involved, and trends in data. o co cn co Ca3 CT

NYC-WTC_000318597

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318597Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →