NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 50 pages

Lab report, WTC debris area air sampling, 2001

Machine-extracted title · confidence 25%

Preliminary health department lab report for air samples around World Trade Center debris site, Sept–Dec 2001.

NYC-WTC_000318290–000318339
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z o z io FBISannpleRe5ults.xls ASBESTOS PERSONAL o

I o o o o 6 00 SAMPLE RESULTS - ASBESTOS AIR - PERSONAL o o o co

DATE LOCATION SAMPLE NUMBER METHOD USED ANALYSIS METHOD LIMIT OF DETECTION Fibers per cc SAMPLE RESULT Fibers per cc LABORATORY I 09/10/01 Landfill 09/10/01 Landfill 09/18/01 Landfill 091801-1 091801-2 091801-4 Phase Contrast Microscopy Phase Contrast Microscopy Phase Contrast Microscopy______ NIOSH 7400 NIOSH 7400 NIOSH 7400 0.093/OC 0.069/oc 0.035/cc PHS Denver PHS Denver PHS Denver I 09/18/01 Landfill 091801-5 Phase Contrast Microscopy . . NIOSH 7400 0,010/cc PHS Denver 09/19/01 Landfill 091801-8 Phase Contrast Microscopy NIOSH 7400 0.144/cc PHS Denver 09/18/01 Landfill 091801-8 Phase Contrast Microscopy NIOSH 7400 0.103/cc ' PHS Denver 09/10/01 Field Blank 091801-9 Phase Contrast Microscopy______ NIOSH 7400 ' PHS Denver 09/18/01 Landfill SI91B-1 Phase Contrast Microscopy______ NIOSH 7400 0.094/cc ’ PHS Denver 09/18/01 * Landfill SI91B-2 Phase Contrast Microscopy______ NIOSH 7400 0.092/cc PHS Denver 09/18/01 Landfill S1918-3 Phase Contrast Microscopy______ NIOSH 7400 0.030/oc ' PHS Denver 09/10/01 Landfill B'SI918-5 Phase Contrast Microscopy NIOSH 7400 0.038/cc ~ PHS Denver 09/10/01 Landfill Wy SI916-9 Phase Contrast Microscopy______ NIOSH 7400 0.135/cc PHS Denver 09/18/01 Landfill w S191B-10 Phase Contrast Microscopy______ NIOSH 7400 0.155/cc " PHS Denver 09/18/01 Landfill SI91S-10 Transmission Electron Microscopy 0.0563/cc " PHS Denver 09/18/01 Landfill SI0ia-14 Phase Contrast Microscopy______ NIOSH 7400 0.175/cc PHS Denver 09/18/01 Landfill SI918-15 Phase Contrast Microscopy NIOSH 7400 0,140/cc " PHS Denver 09/18/01 Field Blank SI918-18 Phase Contrast Microscopy______ NIOSH 7400 PHS Denver 09/19/01 Landfill 091901-2 Phase Contrast Microscopy NIOSH 7400 0.019/cc PHS Denver 09/19/01 Landfill 091901-3 Phase Contrast Microscopy______ NIOSH 7400 0.019/cc PHS Denver 09/19/01 Landfill 091901-4 Phase Contrast Microscopy NIOSH 7400 0.057/cc PHS Denver 09/19/01 Landfill 091901-7 Phase Conlrasl Microscopy NIOSH 7400 0.06B/CC PHS Denver 09/19/01 Landfill 091901-8 Phase Contrast Microscopy NIOSH 7400 0.043/cc PHS Denver 09/19/01 ■ Landfill 091901-9 Phase Contrast Microscopy______ NIOSH 7400 0.116/cc PHS Denver 09/19/01 Field Blank 091901-11 Phase Contrast Microscopy______ NIOSH 7400 PHS Denver o 09/19/01 GroufxJ Zero WTC919-2 Phase Contrast Microscopy______ NIOSH 7400 0.01 Vcc 0.067/cc PHS Denver H 09/19/01 'Field Blank WTC919-3 Phase Contrast Microscopy NIOSH 7400 PHS Denver K 09/19/01 Ground Zero WTC919-4 Phase Contrast Microscopy______ NIOSH 7400 0.077/cc PHS Denver I 09/19/01 ’ Ground Zero WTC910-4 Transmission Electron Microscopy 0.1920/cc PHS Denver S Q 09/19/01 Field Blank WTC919-5 Phase Contrast Microscopy______ NIOSH 7400 PHS Denver 09/19/01 ’ Ground Zero WTC919-6 Phase Contrast Microscopy______ NIOSH 7400 0.007/cc 0.024/cc PHS Denver o o 09/19/01 - Ground Zero WTC919-7 Phase Contrast Microsoopy______ NIOSH 7400 0.046/cc PHS Denver I 0.2777/cc [pHS Denver o 09/10/01 Ground Zero WTC919-7 Transmission Electron Microscopy to

in 1/10/02 a of 35 12:57 PM

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318309Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →