NYC-WTC_000290274
EPA guidance on mandatory and nonmandatory TEM methods for asbestos analysis.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗EPA TEM method guidance and Appendix A substance related to asbestos analysis methods.
NYC-WTC_000318181–000318183OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Code on-ederal Regulations Search Results hnpy/ecfrback.access.gpo.gov/otcgi/efr/o...340&RGN=BAPPCT&SUBSET=SUBSET&FROM=l&ITEM=l
I 7. Abatement area sampling.
a. Conduct final clearance sampling only after the primary containment barriers have been removed; the abatement area has been thoroughly dried; and, it has passed visual inspection tests by qualified personnel. (See Reference 1 of Unit IJI.L.)
b. Containment barriers over windows, doors, and air passageways must remain in place until the TEM clearance sampling and analysis is completed and results meet clearance test criteria. The final plastic barrier remains in place for the sampling period. s c. Select sampling sites in the abatement area on a random basis to provide unbiased and representative samples.
d. After the area has passed a thorough visual inspection, use aggressive sampling conditions to dislodge any remaining dust.
i. Equipment used in aggressive sampling such as a leaf blower and/or fan should be properly cleaned and decontaminated before use.
ii. Air filtration units shall remain on during the air monitoring period.
iii. Prior to air monitoring, floors, ceiling and walls shall be swept with the exhaust of a minimum one (1) horsepower leaf blower.
iv. Stationary fans are placed in locations which will not interfere with air monitoring equipment. Fan air is directed toward the ceiling. One fan shall be used for each 10,000 ft 3 of worksite.
v. Monitoring of an abatement work area with high-volume pumps and the use of circulating fans will require electrical power. Electrical outlets in the abatement area may be used if available. If no such outlets are available, the equipment must be supplied with electricity by the use of extension cords and strip plug units. All electrical power supply equipment of this type must be approved Underwriter Laboratory equipment that has not been modified. All wiring must be grounded. Ground fault interrupters should be used. Extreme care must be taken to clean up any residual water and ensure that electrical equipment does not become wet while operational.
vi. Low volume pumps may be carefully wrapped in 6-rail polyethylene to insulate the pump from the air. High volume pumps cannot be sealed in this manner since the heat of the motor may melt the plastic. The pump exhausts should be kept free.
vii. If recleaning is necessary, removal of this equipment from the work area must be handled with care. It is not possible to completely decontaminate the pump motor and parts since these areas cannot be wetted. To minimize any problems in this area, all equipment such as fans and pumps should be carefully wet wiped prior to removal from the abatement area. Wrapping and sealing low volume pumps in 6-mil polyethylene will provide easier decontamination of this equipment. Use of clean water and disposable wipes should be available for this puipose.
e. Pump flow rate equal to or greater than 1 L/min or less than 10 L/min may be used for 25 mm cassettes. The
f. Sample a volume of air sufficient to ensure the minimum quantitation limits. (See Table I of Unit Hl R f .j.)
8. Ambient sampling.
ISofSS 2/9/02 3:30 PM
CITY_21MClbb_0 08970891
NYC-WTC_000318183
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000290274
EPA guidance on mandatory and nonmandatory TEM methods for asbestos analysis.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275357
Appendix description for TEM and related methods for asbestos analysis in air samples.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320672
Regulatory appendix addressing TEM methods for asbestos analysis.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
4 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
4 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
4 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
3 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
3 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100690
Permit application for a licensed asbestos contractor to clean interior dust at the unoccupied 114 Liberty Street building.
3 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
3 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139560
Updated WTC monitoring scope of work including technical notes on dust control methods and equipment.
3 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140626
Draft scope of work for WTC debris/dust residential cleanup program with compliance requirements and regulatory overview.
3 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000290274
EPA guidance on mandatory and nonmandatory TEM methods for asbestos analysis.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275357
Appendix description for TEM and related methods for asbestos analysis in air samples.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320672
Regulatory appendix addressing TEM methods for asbestos analysis.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318678
Background study draft on asbestos in schools related to WTC, March 2003.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000290274
EPA guidance on mandatory and nonmandatory TEM methods for asbestos analysis.
Similar indexed content
NYC-WTC_000275357
Appendix description for TEM and related methods for asbestos analysis in air samples.
Similar indexed content
NYC-WTC_000320672
Regulatory appendix addressing TEM methods for asbestos analysis.
Similar indexed content
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
Similar indexed content
NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similar indexed content