Air sampling at Fresh Kills, Jan 2002

Machine-extracted title · confidence 42%

EPA air sampling results at Fresh Kills and related sites in January 2002, with several samples affected by equipment issues and metals testing results.

NYC-WTC_000318175–000318179
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC / ER (Jan 10) - Particulate Monitoring (Dataram ) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 616 hours. o Station L values ranged from 0.0 to 171.7 ug/m^with an average of 41.6 ug/m\ o Station N values ranged from 0.3 to 78.6 ug/m^ with an average of 33.8 ug/m\ o Station R values ranged from 0.0 to 98.0 ug/m ’with an average of 34.9 ug/m\

NYC / ER (Jan 10) - Volatile Organics (Mobile Laboratory ) o Benzene did not exceed OSHA TW A PEL (1 ppm) at any of the four locations monitored, including in the debris area at ground level. o Benzene was not detected above the detection lim it (20 ppbv) in 3 of the 4 locations monitored (Washing Tent, Austin Tobin Plaza, and South Tower), including in the debris area at ground level. Direct Reading Instruments

NYC / ER (Jan 10) o Low levels of carbon monoxide noted at nearly all stations during the afternoon monitoring period. o Otherwise, nothing of significance reported.

CITY_21MC1OO_OO897O883

NYC-WTC_000318179

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318179Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Air sampling locations, Oct 2001 · Box unavailable

NYC-WTC_000321273

EPA asbestos air sampling at NYC/ER and NJ/ER with most results below TEM AHERA; one location not sampled and one above standard noted.

10 shared non-person entities · 1 shared topics · similarity 0.976

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

RA sitrep, Jan 11–12 2002

NYC-WTC_000321256

ETA: Jan 11–12 2002 sitrep with air sampling and Fresh Kills results; some equipment issues reported.

Similar indexed content

NYC-WTC_000318160

Asbestos air sampling locations and results; all samples below standard with one indoor exceedance noted.

Similar indexed content