ASBESTOSandOTHERFIBERSbyPCMJVlETHOD7400JssueZdated15August1994^age4^15

A. • E t = ------ , min. Q • L • 10’

NOTE 1: The purpose of adjusting sampling times is to obtain optimum fiber loading on the filter. The collection efficiency does not appear to be a function of flow rate in the range of 0.5 to 16 L/min for asbestos fibers [7]. Relatively large diameter fibers (>3 pm) may exhibit significant aspiration loss and inlet deposition. A sampling rate of 1 to 4 L/min for 3 h is appropriate in atmospheres containing ca. 0.1 fiber/cc in the absence of significant amounts of non-asbestos dust. Dusty atmospheres require smaller sample volumes (^400 L) to obtain countable samples. In such cases take short, consecutive samples and average the results over the total collection time. For documenting episodic exposures, use high flow rates (7 to 16 L/min) over shorter sampling times. In relatively clean atmospheres, where targeted fiber concentrations are much less than 0.1 fiber/cc. use larger sample volumes (3000 to 10000 L) to achieve quantifiable loadings. Take care, however, not to overload the filter with background dust. If 2 50% of the filter surface is covered with particles, the filter may be too overloaded to count and will bias the measured fiber concentration._______________ NOTE 2: -<OSMA’regulations specify a minimum sampling volume’oPreTrfof-aa.gTCursion measurement, and a maximum sampling rate of 2.5 L/min [3]. At the end of sampling, replace top cover and end plugs. Ship samples with conductive cowl attached in a rigid container with packing material to prev^t jostling or damage. \ NOTE: Do not use untreated polystyrene foam in shipping container because electrostatic ) forces may cause fiber loss from sample filter. X

SAMPLE PREPARATION: NOTEI: The object is to produce samples with a smooth (non-grainy) background in a medium with refractive index si.46. This method collapses the filter for easier focusing and produces permanent (1-10 years) mounts which are useful for quality control and interlaboratory comparison. The aluminum "hot block" or similar flash vaporization techniques may be used outside the laboratory [2]. Other mounting techniques meeting the above criteria may also be used (e.g., the laboratory fume hood procedure for generating acetone vapor as described in Method 7400 - revision of 5/15/85, or the non-permanent field mounting technique used in P&CAM 239 [3,7.8,9]). Unless the effective filtration area is known, determine the area and record the information referenced against the sample ID number [1,9,10,11]. NOTE 2: Excessive water in the acetone may slow the clearing of the filter, causing material to be washed off the surface of the filter. Also, filters that have been exposed to high humidities prior to clearing may have a grainy background. 7. Ensure that the glass slides and cover slips are free of dust and fibers. 8. Adjust the rheostat to heat the "hot block" to ca. 70 °C [2]. NOTE: If the "hot block" is not used in a fume hood, it must rest on a ceramic plate and be isolated from any surface susceptible to heat damage. 9. Mount a wedge cut from the sample filter on a clean glass slide. a. Cut wedges of ca. 25% of the filter area with a curved-blade surgical steel knife using a rocking motion to prevent tearing. Place wedge, dust side up. on slide. NOTE: Static electricity will usually keep the wedge on the slide.

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94

CITY_21MC100_003049865

NYC-WTC_000317864

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317864Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →