August 25, 200
N.Y.C. Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Attn: Mr. Bernard Orlan
Re: Report of TEM Analysis
Deal' Mr. Orlan:
Following are the results of transmission electron microscopy (TEM)
analysis of air samples from our Group No. 8760;
Project Name: P.S. 130M, 143 Baxter Street., NY, NY
Location: Entire School, Inside and Out
Samples received: 08/25/02
These results will confirm and document the data transmitted today
to Mr. Yiannis Efstathiou, Project Manager, of our office. The
analyses were performed in strict conformance with, the methodology
of the AHERA Final Rule (40 CER Part 763, Appendix A to Subpart E,
October 30, 1987) for clearance of abatement sites.
The results of the sample analyses are as indicated on the attached
document.
Copies of the bench sheets are also included as stipulated by
AHERA. Results reported as Struct/cc are a function of air volume
collected in the field and are, as such. not verifiable by this
laboratory. This report may be reproduced only in its enoirety and
not without prior permission of this laboratory. If post-abatement
inside samples pass, the response action may be considered to have
been completed.
We are pleased to note that our TEM lab has received full
accreditation from NVLAP, as is currently required for recognized
analysis of TEM air samples for AHERA projects, and also approval
under the NY State DOH ELAP program. These analyses were performed
by ATC d/b/a ATC Associates Inc. Please contact me regarding any
questions relating to these materials.
Very truly yours,
Wichael A. Gorycki, Ph.D.
Director of Electron Microscopy