Air sampling report for silica, P.S. 2M, 2002

Machine-extracted title · confidence 58%

ATC report of silica air monitoring at P.S. 2M during Aug 2002.

NYC-WTC_000316827–000316828
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St.. 10th Fi New York, New York 10010 WWW, ate-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

September 9, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Rc: Air Sampling for Silica P. S. 2M ATC Project No. 15-19125-0341

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air monitoring for silica-containmg dust conducted on August 23. 2002, at the referenced school. The New York City Department of Education (DOE) requested this monitoring prior to the resumption of classes to verify that acceptable indoor air quality is being maintained.

Scope of Work

ATC collected a total of three (3) samples (and one blank) for respirable lust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-rcspirable) particles prior to deposition on the filters. All of the samples w'ere collected indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction according to OSHA Method 142. A copy of the analytical report is attach ..'d.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiere practices. As with all such sampling, there were inherent limitations created by constraints of time, operational and work practice variability', variations in air contaminant concentrations and sampling and analytical accuracy. The results of the sampling represent conditions lound on the dates the samples were collected.

Results

Samples were obtained in the following locations: 1^1 floor Main Lobb), 2*^*^ floor hallway by exit 2&3 and 3’’^ floor hallway by exit 6.

The results of all of the samples were below the deteclioii limit for silica (<10 micrograms per sample).

CITY_21MC100_003033794

NYC-WTC_0003 16827

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000316827Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →