NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling results, P.S. 2M, 8/23/02

Machine-extracted title · confidence 63%

Mercury vapor air sampling results for P.S. 2M, August 23, 2002.

NYC-WTC_000316820–000316821
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St.. 10th Fi New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

August 30, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Mercury Vapor Meyer London School (P. S. 2M) ATC Project No. 15-19125-0341

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for mercury (Hg) vapor conducted on August 23, 2002, at the referenced school. The New York City Department of Education (DOE) requested this sampling prior to the resumption of classes to verify that acceptable indoor air quality is being maintained.

Scope of Work

ATC collected three (3) samples for Hg vapor using Carulite® (Hyd ar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. The samples were sent to PSC Analytical Services, Inc., an American Industria Hygiene Association- accredited laboratory in Reading, PA. One blank tube was also submitted. Analysi.s was performed by means of a mercury vapor analyzer according to NIOSH Method 6009. A copy of the analytical laboratory report is attached.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene practices. The results represent the conditions on the day the samples were collected.

The sampling locations were: 1” floor Main Lobby, 2'“* floor Hallway by Exit 2&3 and 3'"* floor Hallway by Exit 6.

Results

Mercury (Hg) was detected in these samples at levels that yvere inc istlngidshahle from that detected in the blank.

The established regulatory value for mercuiy (O.lmg/m^) is intended for industrial workplace exposures and is not generally applicable to office/school settings. There are no standards for mercury in indoor air in non-industrial situations. The EPA has no .'tandard or guideline for mercury vapor in ambient air.

CITY_21MC100_003033786

NYC-WTC_0003 16820

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000316820Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →