Mr. Bernard P. Orlan August 29, 2002 Indoor Air Quality Assessment Page 2 P.S. 1 M___________________ ATCPro-ectNo. 15-19125-0340

The results of the sampling represent conditions found on the date of t he survey and may not represent conditions found at other times. The information presented in this report should be used by the DOE as a guide to assess the need for further improvemer ts in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-200 '), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRA E); Thermal Environmental Conditions for Human Occupancy (ASHiiAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. I Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLE 1 TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMEI ERS EVALUATED

PARAMETER TARGET LEVEL

Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NI'AAQS) Respirable 65 micrograms per cubic meter USEPA NI'AAQS Particulates (PM2.5) of air (pg/m3) 24-hour average 40 pg/md 24-hour average USEPA - Recommendation for children / sensitive individuals _____ Temperature Summer; 73-79°F at 50% RH Winter: 68-75 °F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA == American Industrial Hygiene Association

CITY_21MC100_003033433

NYC-WTC_000316564

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000316564Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →