NYC 9/11 Public Portal Document
Pace Analytical Services, hie.
1700 Elm Street • Suite 200
Minneapolis, MN 55414
Analytical Method 8290 Analysis Results
Tel: 612-607-1703
Fax; 612- 607-6444
Client - ATC ASSOCIATES
Client’s Sample ID ATC-0822-131M-DX1
Lab Sample ID 103800389
Filename U20929B_15
Injected By BAL
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/22/2002
I CAL Date 08/06/2002 Received 08/24/2002
CCal Filename(s) U20929B_01 & U20929B_17 Extracted 09/17/2002
Method Blank ID BLANK-2163 Analyzed 09/30/2002 12:11
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recover^/
2,3,7,8-TCDF ND 0.0020 2,3,7.8-TCDF-13C 2.00 56
Total TCDF 0.012 0.0020 2.3,7,8-TCDD-13C 2.00 57
1,2.3,7.8-PeCDF-13C 2.00 49
2,3,7,8-TCDD ND 0.0020 2,3.4,7,8-PeCDF-13C 2.00 45
Total TCDD 0.029 0.0020 1,2,3,7.8-PeCDD-13C 2.00 46
1,2,3,4,7,8-HxCDF-13C 2.00 82
1.2.3,7,8-PeCDF 0.027 0.0100 E 1,2,3,6.7.8-HxCDF-13C 2.00 65
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 61
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 47
1.2.3.4,7.8-HXCDD-13C 2.00 88
1.2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 59
Total PeCDD ND 0.0100 1.2,3,4,6.7,8-HpCDF-13C 2.00 34 IP
1,2,3,4,7.8,9-HpCDF-13C 2.00 48
1,2,3,4,7.8-HxCDF ND 0.0100 1,2,3,4,6.7,8-HpCDD-13C 2.00 50
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 47
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7.8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7.8.9-HxCDD-13C 2.00 NA
1.2,3.4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 61
1,2,3,6,7,8-HxCDD ND 0.0100
1,2.3.7,8.9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3.4,6,7,8-HpCDF ND 0.0100 Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.0016 ng/m2
Total HpCDF 0 079 0.0100 (Using ITE Factors)
1,2.3.4,6,7,8-HpCDD 0.075 0.0100
Total HpCDD 0.130 0.0100
OCDF 0.086 0.0200 J
OCDD 0.780 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals inclu de 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Poss ible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061758
RE-ZPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003048605
NYC-WTC_000316122