Mr. Bernard P. Orlan June 21,2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279

individuals and children. The outdoor respirable particulate concentration ranged from 176 fxg/m^ to 181 pg/m^ with an average of approximately 180 pg/m^.

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOCCgnc^trati^

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of CO, and TVOCs were within applicable standards and guidelines. 2. Twenty-one (21) of the indoor measurements for temperature were below the range of 73 to 79°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the summer season. 3. All of the indoor measurements for relative humidity were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. 4. Four (4) of the measurements collected indoors for respirable particulate concentrations were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. 5. All of the indoor CO2 measurement were within the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.

Sincerely, Reviewed by: ATCASSOCL4TESINC.

James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment

CITY_21MC1OO_OO3O32763

NYC-WTC_000315448

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000315448Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →